Ez One Shot BAR CODE SCANNER User Manual - How To Set Parameters
How do you program a scanner with this user's
guide?
.
RESET
. P023$
HOW TO SET PARAMETERS
1. Use the scanner to scan at the bar code representing the function/
parameter you want to set.
2. When you hear two beeps, the new setting will have been defined
or updated into the memory processor.
Default parameters are indicated in bold type and underlined
characters. The character font is ARIAL BLACK. CD = Check Digit.
CDV = Check Digit Verification.
Most settings require only a single bar code, but a few need several
different bar codes to be scanned in order to completely define a
setting. They are:
Preamble / Postamble (maximum 16 digits)
Min Length / Max Length
Accuracy Adjustment
Customer Configuration ID ( Example: Code 39 )
Set A Data - ( CX-Codabar, ABC Codabar, Codabar Coupling).
.
Step 1: Scan CLR PRE/POSTAMBLE.
Step 2: Scan PREAMBLE or POSTAMBLE..
Step 3: Scan any alphanumeric from Full ASCII Table in Groups 32 - 40.
Step 4: Scan PREAMBLE or POSTAMBLE.
Step 1: Scan MIN LENGTH or MAX LENGTH.
Step 2: Scan two digits from Appendix 1.
Step 3: Scan MIN LENGTH or MAX LENGTH
Step1: Scan ACCURACY ADJUSTMENT.
Scan one digit from Appendix 1.
Scan ACCURACY ADJUSTMENT.
Scan CODE 39 SET ID from Group 8.
Scan either one digits or two digits alphanumeric (maximum 2 digits)
from Full ASCII table In Groups 32 - 40.
Scan CODE 39 SET ID from Group 8.
Scan SET A DATA.
Scan one digits any alphanumeric character from Full ASCII Table in
Groups 32 - 40.
Scan SET A DATA.
Step 2:
Step 3:
Step 1:
Step 2:
Step 3:
Step1:
Step 2:
Step 3:
NOTES:
1. The scanner will beep three times as a reminder that a setting is
not yet complete.
2. If you make a mistake, forget a step, etc., scan CLEAR to start
again.
SETTING BAR CODE
10