12 – Troubleshooting
Problems
Possible Reason
Check
Panel displays nothing when switched
on
1.Plug & socket aren’t well connected
2.Panel is not connected properly
3.Fuse is damaged
1.Reinsert plug
2.Reconnect Panel
3.Replace the fuse
The running belt stops while Panel
working normally
The machine’s over-load protection has
been triggered or carbon brushes have
seriously worn.
1. Restart the machine (press Start/Stop)
2. Pull out plug, then reinsert 1 minute later
3. Replace brush or clean dust.
1. Machine can’t be started while
Panel is working normally
2. Panel works normally, but there’s
noise after starting
The input voltage is too low or carbon
brushes have seriously worn.
1. Adjust input voltage.
2. Replace brush or clean dust.
Working normally without any load, but
belt stops when person step on
Belt is too loose
Tighten the belt
Panel works abnormally, no display, or
button operation fails
Outside interference
Having eliminated outside interference, turn off
power and restart 1 minute later
Only Panel works abnormally
Outside interference
Turn off power and restart 10 seconds later
Running & Panel works abnormally
Speed sensor dusty
Clean the dust
Error message E2 shows on display
Safety key not attached
Put safety key on magnetic patch on console
Error message E3 shows on display
Something wrong with display/power
Contact ezygym support
Error message E4 shows on display
Control card fault
Contact ezygym support
Error message E5 shows on display
Motor not working
Contact ezygym support
Error message E6 shows on display
Control Card too hot
Turn off, lubricate running deck, wait 30 minutes