Faber Dama Isola Installation Instructions Manual - Warning
Version 02/12 - Page 5
upper
chimney
cover
lower
chimney
cover
canopy
cabinet base
x = distance from hood to cooktop
(varies depending on installation)
min - 24”, suggested max - 30”
also consult cooktop
manufacturer's recommendation
8
3/8”
min
15
3/8”
max
23
5/8”
2"
36”
FIGURE 4
DUCTED
DIMENSIONS
x
min & max ceiling height examples
x = 30"
min
8'
4"
max
8'
11"
x = 28"
min
8'
2"
max
8'
9"
x = 26"
min
8'
max
8'
7"
x = 24"
min
7'
10"
max
8'
5"
The Tratto Isola chimney is highly adjustable
and designed to meet varying ceiling heights
as indicated in FIGURE 4. The chimney can
be adjusted for ceilings between 7' 10" and
8' 11" depending on the distance between
the bottom of the hood and the cooktop
(distance x in FIGURE 4).
For higher ceiling installations, the High
Ceiling Chimney Kit includes an additional
support structure which adds 21" to the
ceiling heights in FIGURE 4.
DUCTED
INSTALLATION DIMENSIONS
(vented to the outside)
PLAN THE INSTALLATION
This rangehood can be installed as either ducted or ductless. When installed ductless, the rangehood vents out of grates on either
side of the lower chimney. Ductless installations require a Ductless Conversion Kit, available from your dealer.
WARNING! BEFORE MAKING ANY CUTS OR HOLES FOR INSTALLATION, DETERMINE WHICH VENTING METHOD WILL
BE USED AND CAREFULLY CALCULATE ALL MEASUREMENTS.
WARNING
DUE TO THE SIZE
AND WEIGHT OF THIS
RANGEHOOD, THE
SUPPORT MUST BE
FIRMLY ATTACHED TO
THE CEILING. For plaster
or sheet rock ceilings, the
support must be attached
to the joists. If this is not
possible, a support structure
must be built behind the
plaster or sheet rock. The
manufacturer assumes no
responsibility for injury or
damage caused by improper
installations.
!
NOTE: The chimney structure can reduce
down to a 27" minimum height. To reduce
the height, the middle section of the
support structure (FIGURE 5) needs to
be removed. Out of the box, the minimum
chimney length is 32". Subtract 5" from
all minimum ceiling height calculations
in FIGURE 4 if removing the middle
section. Contact Faber at 508-358-5353
for more information.
FIGURE 5
11 7/16”
32”
-