Faber Duet Installation Manual

Summary of Duet

  • Page 1

    Duet installation guide irl uk 40010731-0 842.

  • Page 2

    1 uk irl general 1.1 1.2 1.3 1.4 1.5 30cm a.

  • Page 3

    > > > > 2 uk irl duet 2.1 2.2 2.3 2.4 2.5.

  • Page 4

    3 uk irl 3.1 3.2 3.3 3.4 3.5.

  • Page 5

    > > > > 4 uk irl 3.6 3.7 3.8 3.9 4.0 4.1.

  • Page 6

    5 uk irl 4.2 4.3 5.1 a.

  • Page 7

    > > > > 6 uk irl content 1 introduction ......................................................................................... 7 2 safety and general information .................................................................. 8 3 installation requirements .........................................

  • Page 8

    7 uk irl 1 introduction note: these instructions should be read carefully and retained for future reference. Please leave these instructions with the user. The duet is available in a left and a right version. According to commonly accepted definitions in the fire place business (in front view) the l...

  • Page 9

    > > > > 8 uk irl 2 safety and general information before installation, ensure that the local distribution conditions (identification of the type of gas and pressure) and the adjustment of the appliance are compatible. This gas appliance is factory set and can not be adjusted. This appliance does not...

  • Page 10

    9 uk irl 3 installation requirements note: since the appliance is a source of heat, circulation of air occurs. Therefore it is of importance that you do not use the appliance shortly after a renovation of the home. Due to the natural circulation of air, moist and volatile components from paint, buil...

  • Page 11

    > > > > 10 uk irl determine with the help of appendix a, b and c if the desired routing is possible. To establish this you will need to calculate: the effective height (this is the real difference in height between the upper side of the appliance and the terminal) the total horizontal extension. Thi...

  • Page 12

    11 uk irl 3.7 using an existing chimney. You can connect the appliance onto an existing chimney. The existing chimney then functions as air supply, where a flexible stainless steel liner (to bs715) of 100 mm performs the flue function. Requirements: • any existing chimney used as an air supply must ...

  • Page 13

    > > > > 12 uk irl 4 instruction for installation 4.1 gas connection • installation pipes should be in accordance with bs 6891. Pipe work from the meter to the appliance must be of adequate size. • the complete installation including the meter must be tested for soundness and purged as described in t...

  • Page 14

    13 uk irl • push the glass upwards so that the bottom is free of the groove and now gradually tilt the glass inwards and downwards. (see fig. 4.2 and 4.3) 4.5 placing the appliance • follow the instructions as indicated in the installation instructions before you continue installing. • first make su...

  • Page 15

    > > > > 14 uk irl bottom of the recess. (see fig. 1.2). This because of the extra height of the cover plate. • the chimney breast can be constructed in the same way as described in par. 4.5. • the cover plate can be placed onto the built-in rack now. 4.7 placing the side glas. The placement of the s...

  • Page 16

    15 uk irl 5 commissioning (functional checks) for a pre-delivery check, carry out the following tests: 5.1.1 check function and ignition pilot light and main burner. • check whether the pilot light is not covered by chips, a log or pebbles. • ignite the hearth as is described in the user’s manual. •...

  • Page 17

    > > > > 16 uk irl 5.1.3 checking the initial pressure and the burner pressure the appliance has been adjusted to the correct burner pressure. Adjustment of the burner pressure is not necessary. Because the initial pressure after diy installation is not always correct, we recommend that the initial p...

  • Page 18

    17 uk irl 6 handing over (final check and customer briefing) instruct the customer on the full operation of the appliance and the remote control, including replacement of batteries advise the customer how to clean the appliance including the glass hand over these instructions including the user guid...

  • Page 19

    > > > > 18 uk irl attention: before placing the glass: check the glass sealing rope is in good condition and makes an effective seal. Be sure that there are no fingerprints on the glass. It is not possible to remove those prints after you burn the appliance for a while (they are burnt in). Place the...

  • Page 20

    19 uk irl appendix a: example calculation calculation 1: calculating horizontal extension fig. 2a: flue length c + e = 1m + 1m 2 m elbows d = 2m 2 m total horizontal extension 4 m measure or calculate effective height (hvert) flue length a 1 m roof mounted terminal 1 m total effective height 2 m alw...

  • Page 21

    > > > > 20 uk irl appendix b: flue restrictor determine the right flue restrictor: • calculate the total horizontal- and vertical length of the flue, according to the calculations in appendix a • determine according to the table the right flue restrictor size • when meeting an x, and when the values...

  • Page 22

    21 uk irl appendix c: installation of the flue connection with use of concentric duct material make a hole of ø 153 mm for the wall or roof mounted terminal. The horizontal pipes need to rise away from the appliance at a rate of 3 degrees per metre build the system starting from the appliance on. Ma...

  • Page 23

    > > > > 22 uk irl appendix d: technical specifications flatburner flatburner flatburner country uk / irl uk / irl cat ii 2e+3+ ii 2h3+ appliancetype c11 of c31 c11 of c31 reference gas g20 g31 input (nett) kw 9.7 8.8 efficiency class 2 2 inlet pressure mbar 20 37 gas rate* l/h 1016 347 gas rate* gra...

  • Page 24

    23 uk irl appendix e: dimensions duet r.

  • Page 25

    > > > > 24 uk irl appendix f: dimension duet l.

  • Page 26

    25 uk irl appendix g: dimensions duet r with floorplate.

  • Page 27

    > > > > 26 uk irl appendix h: dimensions duet l with floorplate.

  • Page 28

    27 uk irl appendix j :dimensions convection grid.

  • Page 29

    > > > > 28 uk irl appendix k : dimensions service hatch.

  • Page 30

    29 uk irl.

  • Page 31

    > > > > 30 uk irl.

  • Page 32

    Www.Faber.Nl – info@faber.Nl saturnus 8 nl - 8448 cc heerenveen postbus 219 nl - 8440 ae heerenveen t. +31(0)513 656500 f. +31(0)513 656501.