Faber INCA PRO PLUS Installation Instructions Manual - page 8
Version 10/12 - Page 8
INSTALLATION WITH IB300 / IB600 INTERNAL BLOWER (300
, 600 cfm)
1. InstallthePlateB(FIGURE8)whichcamewiththeinternal
blowerkit,ontopoftherangehoodwiththeholeclosertotheback
ofthehood.Use9screwssuppliedwiththeblowerkit
6. (see FIGURE 13) Removethecoverfromthefieldwiring
compartment with a phillips screwdriver. Feed the Power Supply
Cablethroughtheelectricalknockout.ConnectthePowerSupply
Cabletotherangehoodcable.AttachtheWhiteleadofthepower
supplytotheWhiteleadoftherangehoodwithatwist-ontypewire
connector. Attach the Black lead of the power supply to the Black
lead of the rangehood with a twist-on type wire connector. Attach
thePowerSupplyCablegroundingleadtothegreenscrewprovided.
Replacethecover.
7. Connect the 6" round ductwork to the damper and seal all
connectionswithducttape.Installthegreasefiltersandgreaserail.
(seepage11forinstructions)
8.Turnthepowersupplyon.Turnontheblowerandlight.Ifthe
rangehooddoesnotoperate,checkthatthecircuitbreakerisnot
trippedorthehousefuseblown.Iftheunitstilldoesnotoperate,
disconnect the power supply and check that the wiring connections
have been made properly.
9. CONTINUE TO PAGE 11
FIGURE 8
2. Removethewhiteplasticcoveringandinstall the 4 side trim
piecestotheoutsideofthehoodusing(16)part9bscrews,see
thesidetriminstallationin(FIGURE9).
FIGURE 9
5. Attachthehoodtothecabinetusing(12)9c.screwstothe
cabinet.FIGURE12
FIGURE 12
FIGURE 10
3. Installthemotorkitintothehoodusingthe2screwssupplied
withthemotorkitintothebackofthehood.(FIGURE10)
4.Connectthewirethatcomeswiththemotorkitfromtheside
of the motor to the connection on the inside of the light panel in
thehood.The9holeendofthewireisinstalledinthemotor,the
6holeendisconnectedtothelightpanel(FIGURE11)
FIGURE 11
FIGURE 13
B