  • Page 1

    V-1250x professional multi-room controller amplifier user and installation manual important: proper installation and control of this amplifier requires one or more of the following tools: 1. 12vdc power supply. 2. 3.5mm mono solder-on connectors 1-7pcs. 3. Infrared control system (factor electronics...

  • Page 2

    Table of contents: safety instructions................................................................................ Product overview front panel.............................................................. Master controller amplifier rear panel................................................ V12...

  • Page 3

    Www.Factorelectronics.Com info@factorelectronics.Com safety instructions risk of electric shock do not open important safety instructions • read and keep these instructions. • heed all warnings and follow all instructions contained within this manual. • do not use this unit near water. • clean only ...

  • Page 4

    Www.Factorelectronics.Com info@factorelectronics.Com product overview thank you for choosing the factor electronics v-1250x multi-room controller amplifier. The v-1250x provides the ultimate audio control in six stereo or 12 mono zones without the need for programing. The v-1250x amplifiers are capa...

  • Page 5

    Www.Factorelectronics.Com info@factorelectronics.Com v-1250x master controller/amplifier rear panel dual voltage selector 120v - 240v 12 high quality amplifiers 12 x 50w @ 4ohms 6 x100w @ 8ohms / bridge mono 12 x 30w @ 70 volts removable terminal block connectors ac input 120-240v stereo digital opt...

  • Page 6

    Www.Factorelectronics.Com info@factorelectronics.Com v-1250x-rc infrared remote control features the v-1250x-rc infrared remote control provides complete zone control through the (ir) receiver located on the back panel of the v-1250x. Infrared control requires the use of an external ir system like t...

  • Page 7

    Www.Factorelectronics.Com info@factorelectronics.Com v-1250x installation instructions important: the v-1250x should be situated in a well ventilated location or position. Do not block the vents on the sides or top of the chassis. Proper ventilation is required for normal operation. Do not expose th...

  • Page 8

    V-1250x installation instructions connecting speakers important: do not use the 70volt amplifier setting in bridge mono mode. This will produce an output voltage of 140 volts which will damage the connected speakers and produce distortion. Installation: connecting speakers to the v-1250x use a good ...

  • Page 9

    V-1250x installation instructions connecting sources important: the stereo analog 3.5mm bus input will override the stereo optical input. To use the stereo optical input do not connect to the analog 3.5mm bus input. The bus inputs are the default inputs for all zones. Installation: connecting audio ...

  • Page 10

    V-1250x installation instructions 12vdc triggers important: the 12vdc trigger inputs provide control over zone mute & line/bus source selection as follows with remote bypass on: 1. Master control in: +12vdc= all zones on line input/0vdc (short +/-) = all zones muted 2. Master control out: all zones ...

  • Page 11

    V-1250x installation instructions master 12vdc trigger logic chart www.Factorelectronics.Com info@factorelectronics.Com 11 11 v-1250x logic table command status master trigger in 3.5mm jack inserted? Master trigger in remote dip switch zone n mute in zone n ir in / rs232 zone n zone status out all z...

  • Page 12

    V-1250x installation instructions using the 12vdc triggers for paging installation: connecting 12vdc to the v-1250x line/bus use 22-28awg two conductor wire for all 12vdc trigger connections. Wiring: 3.5mm mono plug (tip + sleeve gnd) installation: connecting 12vdc trigger inputs for a typical backg...

  • Page 13

    V-1250x installation instructions (ir) infrared control (ir frequency 38khz) important: zones 1-6 can be controlled with an infrared repeater system connected to the ir/gnd zone inputs. The zone remote bypass switches must be set in the off position to access infrared functions. Installation: connec...

  • Page 14

    V-1250x installation instructions bus in/out, limiter & master control trigger in/out bus in/out: default zone source the bus in/out is used to send the same input source to any of the six zones or all zones. The bus input can be selected by any or all channels by using the ir remote control and an ...

  • Page 15

    Www.Factorelectronics.Com info@factorelectronics.Com v-1250x installation instructions rs-232 control installation: v-1250x rs-232 serial port control the v-1250x provides an rs-232 serial port connection located on the back panel and uses a db-9 cable connection. The v-1250x supports bi-directional...

  • Page 16

    Www.Factorelectronics.Com info@factorelectronics.Com v-1250x installation instructions rs-232 control function command remarks balance !{z#}ba{b#}+ balance step left !{z#}bl+ balance step right !{z#}br+ zone activity auto update !Za{0/1}+ enable/disable auto update of the zone information when zone ...

  • Page 17

    Www.Factorelectronics.Com info@factorelectronics.Com v-1250x installation instructions rs-232 control queries 17 17 function query response example explanation zone volume ?{z#}vo+ ?{z#}vo{v#}+ ?4vo49+ zone 4 is currently at volume level 49. Mute ?{z#}mu+ ?{z#}mu{0/1}+ ?8mu1+ zone 8 is currently mut...

  • Page 18

    Www.Factorelectronics.Com info@factorelectronics.Com v-1250x installation instructions rs-232 control remote bypass zone switches: the v-1250x provides six zone bypass switches that can be used to bypass (ir) infrared and rs232 control in any or all zones. This feature is used to protect zones from ...

  • Page 19

    Www.Factorelectronics.Com info@factorelectronics.Com v-66 specifications & warranty rms power @ 8 ohms 30 watts x 12 rms power @ 4 ohms 50 watts x 12 rms power @ 8 ohms bridge mode 100 watts x 6 rms power @ 70 volt 30 watts x 12 s/n ratio >90db a weighted thd frequency response 20hz - 20khz input im...