The configuration of the DIP-Switches is as follows:
o
DIP1: Door
o
If DIP1=0
Glass washer and front loading. To begin a new wash cycle, select the
required programme, the appliance is on stand-by meanwhile
o
If DIP1=1
Top loading: To start a new wash cycle, just open and close the door, and
the last used programme is run
o
DIP2: Regeneration
o
If DIP2=0
The appliance does not have descaler
o
If DIP2=1
The appliance has descaler Therefore, if B2 is pressed for 3 seconds, the
descaler cycle is activated
o
DIP3: Time
o
If DIP1=0& DIP3=0
P1=90 / P2=120 / P3=180
o
If DIP1=0& DIP3=1
P1=60 / P2=90 / P3=180
o
If DIP1=1& DIP3=0
P1=90 / P2=120 / P3=180
o
If DIP1=1& DIP3=1
P1=55 / P2=80 / P3=120-∞
o
DIP4: Clinic Line with break tank
o
If DIP4=0: This is not a clinic line appliance
o
If DIP4=1
Vreg (The output Vreg is used as a boiler filler valve)
For the thermostop, in addition to TC, TT should also be considered (PC in
this case). Do not end wash until TC=0 and TT=0