Fantech AEV 1000 Nstallation, Operation And Maintenance Manual - Installation
• Install the unit close to
the outside wall on
which the supply and
exhaust hoods will be
mounted.
• Have a nearby power
supply 120 Volts, 60 Hz.
• Have the possibility of
mounting the unit to
supporting beams.
• Mount the unit as
level as possible.
• Have a certain amount
of heat around the unit
(attic installation is not
recommended).
• Minimize any noise
level that would be
created by the unit in
the living area.
• Have access for future
maintenance.
INSTALLATION
PRACTICAL
TIPS
MOUNTING
LOCATION
The Air Exchanger must be located in a heated space where it will be possible to conve-
niently service the unit.Typically the AEV would be located in the mechanical room or an
area close to the outside wall where the weatherhoods will be mounted. If a basement area
is not convenient or does not exist, a utility or laundry room may be used.
Attic installations are not normally recommended due to:
- the complexity of work to install
- freezing conditions in the attic
- difficulty of access for service and cleaning
Connecting appliances to the AEV It is not recommended, incuding:
- clothes dryer
- range top
- stovetop fan
- central vacuum system
These appliance may cause lint, dust or grease to collect in the AEV , damaging the unit.
NOTE: Connecting any of these type of appliances to the AEV will invalidate your warranty
• Although we recommend installing the unit as shown, the flexibility offered by our centrifugal
external rotor motor allows for the unit to be installed in any position.
• Use #10 wood screws plus vibration insulator grommets supplied with the unit.
4
Fan Tech at
kitchen
::
accessories
U N L I M I T E D
Call 1-800-667-8721 anywhere in the US and Canada -
www.kitchensource.com