Farmcomp wile 55 Operating Instructions Manual - Press On The P- Button.
EN
press on the P- button.
When you see A on the display, release the F- button. If the average
value appears on the display, you can erase the average by
pressing and holding the F- button. The memory is erased, when 0
and then A00 appear on the display.
Note! Always remember to erase the average memory after the
measurement series so that the previous average value will not
affect the average value of the new load.
Average calculation memory can accommodate a maximum of 99
results. If no more results can be added to the memory, the number
on the display will start blinking.
3.4. Adjusting the result
If the quality of the measured material is different from normal, the
result can be incorrect. You can adjust the result shown by the
meter to conform to a reference value.
Adjusting the value upwards
When the measurement result is displayed press twice on the F-
button. Three bars will appear on the upper edge of the display.
Wait for a moment and the result appears on the display again.
Now each time you press the F- button, 0,1 moisture % will be
added to the result.
Adjusting the value downwards
When the measurement result is displayed, press the F- button
three times. Three bars will appear on the lower edge of the
9