FCI ST100 series Configuration Software Manual - page 11
ST100 Series Configuration Software
Fluid Components International LLC
7
Advanced Setup Tab Screens
Select the Advanced Setup branch on the menu tree to access advanced setup items. The User Parameters tab is the first of several tabs across
the top of the screen. Each tab provides a particular menu within the Advanced Setup branch.
The table below summarizes the tabs within the Advanced Setup branch.
Table 2 – Advanced Setup Tabs
Tab Name
Tab Description
Password Level
User Parameters
Shows min/max process variable limits, K Factor, and Flow Damping
1
(ncrease in value = increase in flow damping).
User
Ethernet
Sets Ethernet address values (unit IP address, gateway address, and
subnet mask).
User
Date and Time
Set Clock date and time. Lets users copy the system (host PC) time
and transmit it to the instrument’s battery-backed real time clock.
User
Download Calibration
Lets users download a full calibration to their ST100 via a text file.
Contact FCI to obtain the .txt file that was generated by the factory
linearization software (Cal2).
User
Reboot Device
Lets users perform a warm boot of the ST100.
User
Note 1. Flow damping smooths out flow signal output. Flow response is reduced with high flow damping values.
[User password 2772]
To verify the current configuration of any setup parameter, click Get from Device on any of the Setup menus. After changing any of the setup
parameters, click Send to Device. Click Get from Device again to verify the parameter(s) change. Observe that the changed parameters are now
displayed. The remaining Advanced Setup tab screens are shown below.
Figure 12 – Example User Parameters Tab (Advanced Setup)