FCI ST75 Installation And Operation Manual

Other manuals for ST75: User Manual
Manual is about: MASS FLOW METER

Summary of ST75

  • Page 1

    This page is subject to proprietary rights statement on last page 1 06en003368 rev. G st75/st75v mass flow meter installation and operation guide pre-installation serial number alignment the st75 and st75v (vortab) can be specified with integral or remote electronics. The flow element has a serial n...

  • Page 2

    Fluid components international llc st75/st75v mass flow meter this page is subject to proprietary rights statement on last page 2 06en003368 rev. G specifications media compatibility: air, compressed air, nitrogen, oxygen, argon, co2, ozone, other inert gases, natural gas, and other hydrocarbon gase...

  • Page 3

    St75/st75v mass flow meter fluid components international llc this page is subject to proprietary rights statement on last page 3 06en003368 rev. G fci flow meters may be installed with less than the recommended straight run, but at the risk of limiting performance. Fci offers vortab flow conditione...

  • Page 4

    Fluid components international llc st75/st75v mass flow meter this page is subject to proprietary rights statement on last page 4 06en003368 rev. G instrument wiring before opening the instrument to connect power and signal observe the following esd precautions: use a wrist band or heel strap with a...

  • Page 5

    St75/st75v mass flow meter fluid components international llc this page is subject to proprietary rights statement on last page 5 06en003368 rev. G pulse output activation the st75/st75v provides a pulse output feature. Instruments ordered with volumetric or mass flow units are factory set with tota...

  • Page 6

    Fluid components international llc st75/st75v mass flow meter this page is subject to proprietary rights statement on last page 6 06en003368 rev. G setup interface all parameters on this meter are set through the rs232 interface connection (p3 plug). The rs232 interface allows the instrument to be s...

  • Page 7

    St75/st75v mass flow meter fluid components international llc this page is subject to proprietary rights statement on last page 7 06en003368 rev. G start-up and commissioning 1. Verify all input power and output signal wiring is correct and ready for initial power start-up. 2. Apply power to the ins...

  • Page 8

    Fluid components international llc st75/st75v mass flow meter this page is subject to proprietary rights statement on last page 8 06en003368 rev. G rs232 / fc88 menu control and organization most entries require at least two keystrokes; a capital letter and the [enter] key, or one or more numbers an...

  • Page 9

    St75/st75v mass flow meter fluid components international llc this page is subject to proprietary rights statement on last page 9 06en003368 rev. G example: command v (reference table 3) case: 4-20 ma #1 = flow, 4-20 ma #2 = temperature, namur = low, source out = pulse, sink = alarm1 pressing [v] [e...

  • Page 10

    Fluid components international llc st75/st75v mass flow meter this page is subject to proprietary rights statement on last page 10 06en003368 rev. G the fci instrument requires little maintenance. There are no moving parts or mechanical parts subject to wear in the instrument. The sensor assembly, w...

  • Page 11

    St75/st75v mass flow meter fluid components international llc this page is subject to proprietary rights statement on last page 11 06en003368 rev. G application verification after verifying that the flow meter is functioning, review the application parameters as shown below to verify the calibration...

  • Page 12

    Fluid components international llc st75/st75v mass flow meter this page is subject to proprietary rights statement on last page 12 06en003368 rev. G calibration parameters verification the instrument uses a set of predetermined calibration parameters to process flow signals. Most of these parameters...

  • Page 13

    St75/st75v mass flow meter fluid components international llc this page is subject to proprietary rights statement on last page 13 06en003368 rev. G hardware verification equipment required: • digital multimeter • screwdriver the st75/st75v flow meter is made up of these basic components: • sensor e...

  • Page 14

    Fluid components international llc st75/st75v mass flow meter this page is subject to proprietary rights statement on last page 14 06en003368 rev. G step 3 verify sensor element continuity and resistance. Remove sensor element cable from the bottom of the control circuit assembly. Note that two of t...

  • Page 15

    St75/st75v mass flow meter fluid components international llc this page is subject to proprietary rights statement on last page 15 06en003368 rev. G transmitter circuit calibration check (delta r verification) references • delta ‘r’ data sheet equipment • fc88 communicator or equivalent. • dvm • del...

  • Page 16

    Fluid components international llc st75/st75v mass flow meter this page is subject to proprietary rights statement on last page 16 06en003368 rev. G intentionally left blank.

  • Page 17

    St75/st75v mass flow meter fluid components international llc this page is subject to proprietary rights statement on last page 17 06en003368 rev. G appendix a - approval information eu information flow/liquid level/temperature instrumentation visit fci on the worldwide web: www.Fluidcomponents.Com ...

  • Page 18

    Fluid components international llc st75/st75v mass flow meter this page is subject to proprietary rights statement on last page 18 06en003368 rev. G specific conditions of use per fm16atex0008x 1. The ambient temperature range and applicable temperature class of the sensor probe is based on the maxi...

  • Page 19

    St75/st75v mass flow meter fluid components international llc this page is subject to proprietary rights statement on last page 19 06en003368 rev. G t2 / t300°c: -40°c t3 / t200°c: -40°c t1: -40°c safety instructions for the use of the st51/75 flow meter in hazardous areas approval fm16atex0008x/iec...

  • Page 20

    Fluid components international llc st75/st75v mass flow meter this page is subject to proprietary rights statement on last page 20 06en003368 rev. G gb irl english - safety instructions these safety instructions are valid for the fluid components, st51/75 flow meter to the ec type approval certifica...

  • Page 21

    St75/st75v mass flow meter fluid components international llc this page is subject to proprietary rights statement on last page 21 06en003368 rev. G f b l consignes de sécurité ces consignes de sécurité sont valables pour le modèle st51/75 de la société fluid components (fci) conforme au certificat ...

  • Page 22

    Fluid components international llc st75/st75v mass flow meter this page is subject to proprietary rights statement on last page 22 06en003368 rev. G p português - normas de segurança estas normas de segurança são válidas para os fluid components, st51/75 conforme o certificado de teste de modelo n.º...

  • Page 23: Appendix B - List Commands

    St75/st75v mass flow meter fluid components international llc this page is subject to proprietary rights statement on last page 23 06en003368 rev. G appendix b - list commands table 5. St75/st75v list of single letter commands table 6. St75/st75v list of cli commands command mnemonic command functio...

  • Page 24

    Fluid components international llc st75/st75v mass flow meter this page is subject to proprietary rights statement on last page 24 06en003368 rev. G table 6. St75/st75v list of cli commands, cont. Command line password: 357 command mnemonic command function command description data type k[1-4] r/w k...

  • Page 25

    St75/st75v mass flow meter fluid components international llc this page is subject to proprietary rights statement on last page 25 06en003368 rev. G note: when invoking a write function, there must be a space separating the command characters and the data value. All read and write functions are comp...

  • Page 26

    Fluid components international llc st75/st75v mass flow meter this page is subject to proprietary rights statement on last page 26 06en003368 rev. G intentionally left blank.

  • Page 27: Appendix C - Drawings

    St75/st75v mass flow meter fluid components international llc this page is subject to proprietary rights statement on last page 27 06en003368 rev. G appendix c - drawings.

  • Page 28

    Fluid components international llc st75/st75v mass flow meter this page is subject to proprietary rights statement on last page 28 06en003368 rev. G.

  • Page 29

    St75/st75v mass flow meter fluid components international llc this page is subject to proprietary rights statement on last page 29 06en003368 rev. G.

  • Page 30

    Fluid components international llc st75/st75v mass flow meter this page is subject to proprietary rights statement on last page 30 06en003368 rev. G.

  • Page 31

    St75/st75v mass flow meter fluid components international llc this page is subject to proprietary rights statement on last page 31 06en003368 rev. G.

  • Page 32

    Fluid components international llc st75/st75v mass flow meter this page is subject to proprietary rights statement on last page 32 06en003368 rev. G.

  • Page 33

    St75/st75v mass flow meter fluid components international llc this page is subject to proprietary rights statement on last page 33 06en003368 rev. G appendix d - customer service fci provides full in-house technical support. Additional technical representation is also provided by fci field represent...

  • Page 34

    Fluid components international llc st75/st75v mass flow meter this page is subject to proprietary rights statement on last page 34 06en003368 rev. G warranty repairs or returns fci prepays ground transportation charges for return of freight to the customer’s door. Fci reserves the right to return eq...

  • Page 35: Ra #______________

    St75/st75v mass flow meter fluid components international llc this page is subject to proprietary rights statement on last page 35 06en003368 rev. G fci document no. 05cs000004d [u] 1. Return customer information returning company’s name: _____________________________phone# _________________________...

  • Page 36

    Fluid components international llc st75/st75v mass flow meter this page is subject to proprietary rights statement on last page 36 06en003368 rev. G fci document no. 05cs000004d [u] the following return authorization request form and decontamination statement must be completed, signed and faxed back...

  • Page 37

    St75/st75v mass flow meter fluid components international llc this page is subject to proprietary rights statement on last page 37 06en003368 rev. G goods furnished by the seller are to be within the limits and of the sizes published by the seller and subject to the seller’s standard tolerances for ...

  • Page 38

    Fluid components international llc st75/st75v mass flow meter this page is subject to proprietary rights statement on last page 38 06en003368 rev. G notes.

  • Page 39

    St75/st75v mass flow meter fluid components international llc this page is subject to proprietary rights statement on last page 39 06en003368 rev. G notes.

  • Page 40

    St75/st75v mass flow meter fluid components international llc 06en003368 rev. G notice of proprietary rights this document contains confidential technical data, including trade secrets and proprietary information which is the property of fluid components international llc (fci). Disclosure of this d...