Fermax MDS Technical Manual - page 22
MDS
MDS
Page 22
* Residential Complex
WXYZ
TUV
PQR
GHI
MNO
DEF
ABC
JK L
3
4
2
1
7
8
6
5
9
0
A
B
C
*
#
1
2
3
4
5
6
7
8
9
A
0
B
LCD DIGITAL SYSTEM
1
2
3
4
5
6
7
8
9
A
0
B
LCD DIGITAL SYSTEM
1
2
3
4
5
6
7
8
9
A
0
B
LCD DIGITAL SYSTEM
1
2
3
4
5
6
7
8
9
A
0
B
LCD DIGITAL SYSTEM
1
2
3
4
5
6
7
8
9
A
0
B
LCD DIGITAL SYSTEM
TELEFONOS
D2
BUS
+ D1
-
6
2
PGM
1 2
1
1
6
4
3
2
4
2 3
3
D1
BUS
26
D2
3
5
-
- +
V
6 4
6
6
2 1
7
34
2
1
3
2
6 1
4
6
4
4
2 3 6
6
3
8
61 4
2 1
34
2 1
REF. 2425
TELEFONOS
D2
BUS
+ D1
-
6
2
PGM
1 2
1
1
6
4
3
2
4
2 3
3
D1
BUS
26
D2
3
5
-
- +
V
6 4
6
6
2 1
7
34
2
1
3
2
6 1
4
6
4
4
2 3 6
6
3
8
61 4
2 1
34
2 1
REF. 2425
1
2
3
4
5
6
7
8
9
A
0
B
LCD DIGITAL SYSTEM
Example of a call from system. MDS Digital - MDS City
WXYZ
TUV
PQR
GHI
MNO
DEF
ABC
JK L
3
4
2
1
7
8
6
5
9
0
A
BC
*
#
B
2
6
FXL
PANEL
0
2
+-
SB
SA
CT
6
VM
AB
GA
12Vdc
REF
. 2405
UNIDAD CENTRAL MDS MDS CENTRAL UNIT
DECODERS
D2
D1
+
-
M
V
-
+
G
CN1
CN2
CN8
CN7
SA SB
CT
M
V
6
2
-
+
CN3
SA
M
CT V
SB
6
2
-
+
CN4
CN5
CN6
OUT
IN
+
-
+
-
SW1
SW2
ON
ON
CN1
CN2
CN8
CN7
SA SB
CT
M
V
6
2
-
+
CN3
SA
M
CT V
SB
6
2
-
+
CN4
CN5
CN6
OUT
IN
+
-
+
-
SW1
SW2
ON
ON
123
456
789
A0
B
LCD DIGIT
AL
SYSTEM
123
456
789
A0
B
LCD DIGIT
AL
SYSTEM
123
456
789
A0
B
LCD DIGIT
A
L
SYSTEM
12 Vdc
TELEFONOS
D2
BUS
+
D1
-
6
2
PGM
12
1
1
6
4
3
2
4
23
3
D1
BUS
26
D2
3
5
-
-
+
V
6
4
6
6
2
1
7
34
2
1
3
2
61
4
6
4
4
23
6
6
3
8
61
4
2
1
34
2
1
REF
. 2425
TELEFONOS
D2
BUS
+
D1
-
6
2
PGM
12
1
1
6
4
3
2
4
23
3
D1
BUS
26
D2
3
5
-
-
+
V
6
4
6
6
2
1
7
34
2
1
3
2
61
4
6
4
4
23
6
6
3
8
61
4
2
1
34
2
1
REF
. 2425
12 Vdc
TELEFONOS
D2
BUS
+
D1
-
6
2
PGM
12
1
1
6
4
3
2
4
23
3
D1
BUS
26
D2
3
5
-
-
+
V
6
4
6
6
2
1
7
34
2
1
3
2
61
4
6
4
4
23
6
6
3
8
61
4
2
1
34
2
1
REF
. 2425
TELEFONOS
D2
BUS
+
D1
-
6
2
PGM
12
1
1
6
4
3
2
4
23
3
D1
BUS
26
D2
3
5
-
-
+
V
6
4
6
6
2
1
7
34
2
1
3
2
61
4
6
4
4
23
6
6
3
8
61
4
2
1
34
2
1
REF
. 2425
12 Vdc
HIGH PERFORMANCE
MUL
TIPLEXED DIGIT
AL
SYSTEM
ST
OP
HIGH PERFORMANCE
MUL
TIPLEXED DIGIT
AL
SYSTEM
ST
OP
HIGH PERFORMANCE
MUL
TIPLEXED DIGIT
AL
SYSTEM
ST
OP
Decoder Programming:
From: 101 to 140.
Decoder Programming:
From: 1201 to 1280.
Note:
In Interior Blocks remember that when programming
decoders, the first two digit
s of the number assigned to
the decoders (residence number) should match the inte-
rior block number
.
For example for
BB
VV
, it will be
BB
: Block (the initial 0 is
not included) - VV
: Residence
* Block 1: From
101 to
140
* Block 12: From
12
01 to
12
80
The Block Number must always be programmed on the
corresponding Internal Block Panel. In MDS City Panels
(Digitiser) programming is carried out from the MDS Digit
al
Panel in the General Entrance.
Access 1
BLOCK 1
Access 1
BLOCK 2
Access 2
- Call residence 0058 in Block 12
Press:
1
2
5
8
Calls from the GENERAL ENTRANCE
in this case,
the first two
digit
s match
the block
number (12)
in this case, the first
two digit
s match the
block number (01)
- Call residence 0027 in Block 1
Press:
1
2
7
(the initial 0s are not included)
residence
number
(2 digit
s)
block
number
(2 digit
s)
residence
number
(2 digit
s)
block
number
(2 digit
s)
in this type of call, the
p
anel’
s digitiser adds
the block number called
as a prefix, in this case
block number: 1
- Call residence 0027 in Block 1
Press:
2
7
(button)
Calls from the INTERIOR BLOCK
- Call residence 0058 in Block 12
Press:
5
8
(button)
in this type of call,
the p
anel’
s
digitiser adds the
block number
called as a prefix,
in this case block
number: 12
residence
number
(2 digit
s).
The button
determines the
last 2 digit
s in
the call address
block
number
(2 digit
s)
block
number
(2 digit
s)
residence
number
(2 digit
s).
The button
determines the
last 2 digit
s in
the call address
Panel installed in:
General Entrance
Interior Blocks
System Chosen:
MDS Digital
MDS Direct
Residences per Block
B1
B12
3 General Entrances
General Entrance
Guard Unit
Residence 58
MDS Address
1258
Residence
27
MDS Address
0127
Residential
Floors
40
80