Fetco CBS-2051E User Manual - page 11
11
Temperature Settings
Parameter
Name
Range
Default Setting
Comment
7
Water Temp. (°F)
180°F - 208°F
200°F
Inside tank. Will be slightly lower at
spray head. To display in ° Celsius,
see # 58 in Advanced Settings.
8
Hot Water Service
A (auto) / On / Off
A (auto)
A= Faucet will dispense only when not
brewing.
On=Faucet always enabled.
Off=Faucet always disabled.
9
Brew at Set
Temperature
0 - 1
1
0=Will brew at any temperature
1=Will brew only at set temperature.
Note: Changes will not take effect
until one full brew cycle is completed
after the change is made.
Parameter
Name
Range
Default Setting
Comment
10
Enter Advanced
Settings &
Diagnostics
0 - 1
0
0 = Skip Advanced Settings &
Diagnostics. Loop back to start of
batch programming cycle.
1 = Enter Advanced Settings &
Diagnostics.
Press STOP to continue
Important! To save your changes, press
twice to exit programming mode and return to operating mode.
Advanced Settings and Diagnostics
Address
Description
Range
Default
Comment
50
Water Level
in Tank
0 - 1
Tests if water is touching probe.
0 = Tank is less than full
1 = Tank is full
52
Brew Basket
Sensor State
(left / right)
0 - 1
To test, slide the brew basket in and out. Display
should toggle between 0 and 1.
0 = Brew basket out. 1 = Brew Basket in.
55
Tank Temperature
180°F - 208°F
Displays current tank temperature.
56
Brewer Model
Number
31 - 52
Must be set for the correct model number of the
brewer: 51 for CBS-2051e,
52 for CBS-2052e and CBS-2052e20.
57
Reload Defaults
0 - 1
0
Changes all settings to default factory settings.
0 = Do not reload defaults
1 = Reload all default settings
If 1 is selected, you must advance to the next
address for this change to take effect.
Does not change address 56 – model number.
58
Temperature Scale F or C
F
F = Displays temp in degrees Fahrenheit
C = Displays temp in degrees Celsius
59
Water Volume
Scale
GAL or LTR
GAL
GAL = Displays volume in gallons
LTR = Displays volume in liters