CBS_2151XTS—Single 1½ gallon version Electrical Configurations
USA and Canada
CBS_2151XTS—Single 1½ gallon version Electrical Configurations
Configuration Code
Plastic
Brewbasket
Stainless Steel
Brewbasket
Heater
Configuration
Voltage Phase
Wires
Electrical
Connection
KW Amp
Draw Gallon/Hour
(1½ gallon per batch
E215151
E215151M
2 X 3.0 kW
208-240
1
2+G
Hardwired
4.6-6.1
22.4-25.8
15.3 gal/58 liters
EXPORT/Japan
CBS_2151XTS—Single 1½ gallon version Electrical Configurations
Configuration Codes
Plastic
Brewbasket
Stainless Steel
Brewbasket
Heater
Configuration
Voltage Phase
Wires
Electrical
Connection
KW
Maximum
Amp Draw
Brew-Volume/Hour
(1½ gallon per batch)
E215180
E215180M
1 X 5.0 kW
200-240
1
2+G
Hardwired
3.6
17.7
11.6 gal/44liters
E215181
E215181M
2 X 3.0 kW
200-240
1
2+G
Hardwired
4.3
21.3
14.3 gal/54 liters
North America & International Versions
CBS_2151XTS—Single 1½ gallon version Electrical Configurations
Configuration Code
Plastic
Brewbasket
Stainless Steel
Brewbasket
Heater
Configuration
Voltage Phase
Wires
Electrical
Connection
KW Amp
Draw Gallon/Hour
(1½ gallon per batch)
E215190
E215190M
1 X 4.0 kW
200-240
1
2+G
Hardwired
4.1
14.2-17.1
9.3 gal/35 liters
E215191
E215191M
1 X 5.0 kW
200-240
1
2+G
Hardwired
5.1
17.7-21.3
12.7 gal/48 liters
E215192
E215192M
2 X 3.0 kW
200-240
1
2+G
Hardwired
6.1
21.3-25.5
15.3 gal/58 liters
E215193
E215193M
2 X 2.3 kW
200-240
1
2+G
Hardwired
4.7-6.1
22.1-25.5
14.0 gal/53 liters
CE EXPORT
CBS_2151XTS—Single 1½ gallon version Electrical Configurations
Configuration Codes
Plastic
Brewbasket
Stainless Steel
Brewbasket
Heater
Configuration
Voltage Phase
Wires
Electrical
Connection
KW
Maximum
Amp Draw
Brew-Volume/Hour
(1½ gallon per batch)
(CE) E215161
(CE) E215161M
2 X 2.3 kW
230/400
2
2L,N,PE
Hardwired
5.6
12.4
14.0 gal/53 liters
Has CE and NSF-4 certification. Internal EMI filter. Not cUL and UL listed