Franco Belges Le Continental 174 07 53 Technical Manual - page 3
1. Description of the unit
1.1. Description
Flued oil stove with vaporizing burner (Norm EN1)
1.2. Optional equipment
¤ Ground vat
1.3. Specifications
Nominal Heat Output (NF D 35.001) . . . kW
6,5
. . . . . . . . . . . . . . . . . . . . . . Btu/hr
26.000
Oil consumption at :
- maximum speed . . . . . . . . . . . . . . l/h
0,81
. . . . . . . . . . . . . . . . . . . . . . . gal/hr
0,22
- minimum speed . . . . . . . . . . . . . . l/h
0,25
. . . . . . . . . . . . . . . . . . . . . . . gal/hr
0,066
Chimney draft required at :
- maximum speed . . . . . . . . . . . . . . Pa
15
- minimum speed . . . . . . . . . . . . . . Pa
6
Weight . . . . . . . . . . . . . . . . . . . . kg
55
USA/CANADA - Connection to a L.VENT chimney :
Nominal heat output . . . . . . . . . . . Btu/h
19 600
. . . . . . . . . . . . . . . . . . . . . . . . kW
5.75
Oil consumption at nominal speed . USgal/h
0.198
. . . . . . . . . . . . . . . . . . . . . . . . l/h
0.75
Chimney draft . . . . . . . . . . . . . . “w.c.g
0.06
. . . . . . . . . . . . . . . . . . . . . . . . Pa
15
7
9
8
1
2
3
4
5
6
10
11
12
13
Fig. 1 - Description
1 - Cover
2 - Top plate
3 - Flue baffle
4 - Flue box
5 - Draught regulator
6 - Carburettor
7 - Draught control
8 - Combustion chamber
9 - Main door
10 - Catalyser ring
11 - Catalyser cover
12 - Catalyser body
13 - Air inlet holes
5 4 0
4 6 0
Ø 1 2 0 / 1 2 7
8 0 5
5 3 0
3 5 0
805 mm - 31 3/4"
Ø 120 / 127 mm - Ø 5"
540 mm - 21 1/4"
530 mm - 20 4/5"
350 mm - 13 3/4"
460 mm - 18"
Fig. 2 - Dimensions in mm
Document n° 952-3 EN ~ 02/03/2000
Continental
Poêle à combustible liquide
Notice de référence
3