1.4. Operating principle
Furnace oil is fed to the burner floor (fig. 1) where is it
ignited by means of a firestarter. The heat produced by
this flame brings the burner temperature to the required
level to vaporize the fuel. Oil will only burn as a vapour
not a liquid.
Room combustion air enters the burner through the air
inlet holes (# 13, fig. 1).
In the center of the burner is the catalyser (# 12, fig. 1)
which aids in vaporizing the fuel. When the stove is
operation, the catalyser glows red. The stove should not
be used with out both the catalyser (# 12, fig. 1),
catalyser top (# 11) and ring (# 10).
A de-scaling lever (# 1, fig.8) can be pushed and pulled
in and out as well as turning slightly at the same time to
keep the inlet pipe clear of carbon buildup.
The stove float regulator contains a filter to trap
impurities.
A safety lever controls fuel flow. Oil can only enter the
float chamber when the safety lever is depressed.
Oil temperature variations will affect the oil flow into the
float chamber. A float in the chamber raises the fuel
level available to the burner.
The carburetor is also controlled by a control knob
which turns from “0" (off) to ”6" (high setting).
A draft regulator (# 3, fig. 7) ensures a constant air
intake to the burner regardless of external factors.
2. Installation instructions
USA / CANADA : The installation of this stove must com-
ply with state and local requirements and the standard
CSA B139.
2.1. Position of the unit
- The position of the appliance must be chosen very
carefully in order to obtain the best possible results for
heat distribution.
- Position the unit to comply with the minimum
c l e a r a n c e s t o c o m b u s t i b l e m a t e r i a l . M i n i m u m
clearances are shown from the vertical portion of the
chimney connector. Check that no overhead cross
members in the ceiling will be cut. Reposition unit if
necessary, being careful not to move closer than the
minimum clearances.
- Outside air : For the oil stove to function properly, an
adequate supply of combustion air is required.
2.2. Chimney
- Ensure that the flue has sufficient draught (refer to
technical details).
- Minimum flue diameter, 10 cm (4" I.D).
- The chimney must be at least 4.5 m (15 ft high).
- The flue must not be shared with any other appliance.
- Downdraughts caused by obstacles close to the
chimney top may sometimes be prevented by fitting an
anti-downdraught cap to the top of the chimney.
- The chimney must have a constant cross section. Too
large a flue could affect the chimney draught.
- The chimney must be soundly constructed, in order to
prevent cold air infiltration.
- The flue must be well insulated, water and air tight. A
chimney with a cold internal surface can prevent a good
chimney draught and condensation will occur.
-The flue must be swept at least once a year.
2.3. Chimney connector
- The appliance must be as close as possible to the
chimney. Avoid horizontal flue connection pipes which
can dangerously restrain functioning of the appliance.
The connector pipe should be standard black painted or
blued steel pipe of not less than 30 gage; 304 grade
stainless steel of not less than 30 gage; or 1 mm
viterous enamelled steel, with a maximum diameter of
5 inch O.D. - (127 mm). It is the installer’s responsability
to conform to local building standards and requirements
with regard to installation.
Single wall pipe may be utilized being careful to
maintain clearances to any combustible surface. (fig. 3)
Once the stove has been properly installed the chimney
draught must be checked with a draught meter.
If the chimney draught is excessive or irregular, a
draught stabilizer (barometric damper) must be
installed to the connector pipe.
2.4. Connection to a L.VENT chimney
USA / Canada
: The 174 07 53 appliance is certified to
be connected to a 5" L.VENT chimney with its nominal
heat output limited to 19600 Btu/h (5.75 kw) .This will be
achieved by replacing the float-regulator (carburator)
(# 19 fig. 9).Please contact your dealer to have this
alteration done.
WARNING. FRANCO-BELGE is not responsible for
any incidental or consequential damages if this
operation is not done.
Figure 3 - Minimum clearances to combustible surfaces
Document n° 952-3 EN ~ 02/03/2000
Continental
Poêle à combustible liquide
4