9.6 CONTINUOUS KEY
This key enables or disables the continuous dose distribution
function.
The display shows the following:
where
XXXXXXXX
can be
ENABLED
or
DISABLED
Use key T1 and key T2 if the parameter is to be changed.
This function is pre-set to
ENABLED
mode.
Pressing key T5 enables the next setting to be selected.
9.7 TEA/MIXED HOT WATER
This function allows the mixed hot water mode to be enabled
or disabled.
The display shows the following:
where
XX
can be
YES
or
NO.
Press key T1 and key T2 if the parameter needs to be changed.
This function is pre-set to the
YES
mode.
Pressing key T5 enables the next setting to be selected.
9.8 PRE-INFUSION
This function allows the pre-infusion mode to be enabled
or disabled.
The display shows the following:
where
XXXXXXX
can be
YES
or
NO.
Press key T1 and key T2 if the parameter needs to be changed.
This function is pre-set to the
Enabled
mode
.
Pressing key T5 enables the On and Off parameters
of the pre-infusion function to be accessed and set.
9.8.1 PRE-INFUSION PARAMETERS
The pre-infusion On and Off times can be programmed.
The display shows the following:
where zzzzzz is the type of coffee
X.X = total pre-infusion On time
YY = ON or OFF
mixed water
XX
9.3 TELEPHONE SUPPORT
A telephone number can be entered which is displayed in
the case of certain alarms.
The display shows the following:
where
XXXXXXXX
represent the digits composing the tele-
phone number.
Press key T5 to proceed to the next menu.
9.4 KEYBOARD TYPE
The type of PUSHBUTTON STATION used for dosing can
be set and this is applicable for all pushbutton stations.
The machine is already pre-set with the correct keyboard.
The display shows the following:
where
XXXXXXXX
indicates the two types of keyboards
which can be selected:
Espresso - 2Espresso - Coffee - 2Caffees ( already preset)
Espresso - Coffee - 2Espresso - 2Coffees
WARNING!
:
changing the type of keyboard is
not recommended. Changing the pre-set type will
produce an inconsistency between the silkscreen
printed front panel and the keyboard selected.
Pressing key T5 enables the next display to be viewed after
the setting the type of keyboard has been completed.
9.5 DOSES PROGRAMMING
This function allows the doses programming to be enabled
or disabled.
The display shows the following:
where
XXXXXXXX
can be
ENABLED
or
DISABLED
Press key T1 and key T2 if the parameter needs to be changed.
This function is pre-set to the
ENABLED
mode.
Pressing key T5 enables the next setting to be selected.
Tel. Support
XXXXXXXX
Keyboard Type
XXXXXXXX
Doses Progr.
XXXXXXXX
continuous key
XXXXXXXX
Pre-infusion
XXXXXXX
Preinf. YY sec
zzzzzzzzz
X.X