Gainsborough e50 Installation Manual - page 7
3
Remove the fixing screws and lift the casing up and away from the
engine assembly.
4
Offer the unit onto the finished wall surface in the desired position and mark the three fixing
points. Drill and prepare the fixing holes using the fixings provided if suitable.
!
In addition to the guide that follows it is essential that the written instructions on pages 4 and 5 are read and understood, and
that you have all the necessary components before commencing installation. Failure to install the product in accordance with
these instructions may adversely affect the warranty terms and conditions. Do not undertake any part of this installation
unless you are qualified to do so. Prior to starting, ensure you are familiar with the necessary plumbing and electrical
regulations and legislation required to install the product correctly and safely.
Aqualisa Products Ltd reserves the right to revoke the terms of the warranty should access to the service connections be denied
by the use of solid setting infill material.
Pipework Installation instructions
6
If using bottom entry pipe work connection, rotate the inlet elbow into the correct position and fix the unit to the wall using
the screws provided, if suitable.
7
Flush through the water supply pipe allowing it to discharge safely to waste.
5
Remove the service tunnel and set aside.
8
Remove the relevant pipe work and cable entry points from the relevant section of the shower unit using a suitable tool.
We recommend making good the cut out section using a round file. Ensure the shower unit fits over the cable
and pipe work correctly.
1
Remove the warning label and outlet bung from the unit, if fitted.
2
Set the temperature dial to the full cold position to ensure correct alignment during reassembly.
!
Ensure the internal flow/temperature control mechanism is not moved during assembly once the cover has been removed.
!
Some modern fluxes can be extremely corrosive and, if left in contact will attack the working parts of this unit. All soldering
must be completed and pipe work thoroughly flushed out in accordance with current Water Supply Regulations prior to
connection of the product
7
!
THIS PRODUCT IS NOT SUITABLE FOR TOP ENTRY PIPEWORK.
E50 instructions :Layout 1 18/11/14 10:42 Page 7