Galanz XQG60-A708E Service Manual - page 13
12
Pulley, motor and absorber
1
①Remove the back cover
②Loosen the big screw nut from the pulley and take out
the belt
③Remove the pulley
2
①Take off the motor connection plug wire
②Remove two bolts from motor holder, and take out
the motor bush.(picture 14)
③Follow the arrow to take off the motor (picture15)
④Ensure the bush is in the motor holder while reset the
motor
14
15
3
①Remove the fixed bolt from absorber.
②Take out the absorber
③Ensure tighten the fixed bolt while reset the absorber
to avoid the noise from spin
Clear draining pump filer
1
⒉ Turn filer left and take off the water pump
filer(picture 16)
② Clear the stuff from water pump filer(photo 17)
③Put back the filer in to right position after clear
⒉ Please well set the dam-board after well set the
filer
16
17
Water pump
①Remove the control panel, dam-board and front cover
②Remove two bolts from water pump
③Remove water pump wires
④Hole the water pump pull up
⑤ Remove all the hose from water pump
Remove the pump (remark: photo 8 shows the well
set water pump)
18