  • Page 1

    Model 550550 control un it user’s manual this user’s manual is also available online in english, french, german, italian, japanese, and spanish at www.Gameready.Com under products..

  • Page 2

    Description of device _______________________________________ 2 introduction to game ready _________________________________ 3 detailed instructions for use _________________________________ 4 using your game ready system _____________________________ 7 indications for use __________________________...

  • Page 3

    En-2 d e s c r i p t i o n o f d e v i c e game ready system: the following items are included in your game ready system: a control unit, an ac adapter, a power cord, a connector hose, and a welcome packet, containing the user’s manual and other information about the system. Each wrap (comprised of ...

  • Page 4

    En-3 based in concord, california, and founded in 1998, game ready ® (coolsystems, inc.) is a best-in-class sports medicine and orthopedic medical device that helps athletes and patients recover from injury or orthopedic surgery. The game ready system with accel ™ technology gives healthcare provide...

  • Page 5

    En-4 modes of operation manual mode: the system defaults to this mode, and allows the user to adjust time and pressure settings. Program mode: this mode allows the user to choose one of six programs that provide treatment for a set time then sleep (no treatment) for a set time, continuously, at a sp...

  • Page 6

    En-5 adjusting temperature: turn knob counter-clockwise for less cold therapy turn knob clockwise for more cold therapy display status bar: off (mute) on indicates selected mode indicates unit is paused indicates unit is playing other icons: indicates an error. See troubleshooting pages 17-18 for er...

  • Page 7

    En-6 when the system is running in program mode: displays the amount of run time remaining run time count-down bars displays the amount of sleep time remaining when the system is running in manual mode: displays the amount of run time remaining sleep time count-down bars when selecting a program: pr...

  • Page 8

    En-7 to operate your game ready system, you need: • a control unit filled with ice and water • a game ready supplied power supply • a connector hose • a wrap (a heat exchanger and sleeve) notes: • the wrap is comprised of an inner heat exchanger and an outer sleeve. The combination of sleeve and hea...

  • Page 9

    En-8 u s i n g y o u r g a m e r e a d y s y s t e m step 3: close the ice box door. Make sure you hear it click. Step 4: : place the control unit in the location where you plan to use it. The control unit should only be used in the upright orientation as shown. The control unit will leak if placed ...

  • Page 10

    En-9 if you have any problems with the set-up of your game ready system, please contact game ready customer service; from the u.S. Call toll-free at 1.888.426.3732, from outside of the u.S. Call +1.510.868.2100. Warnings: • follow the recommendations of your health care practitioner. • improper plac...

  • Page 11

    En-10 step 10: you can choose to operate in either manual mode or program mode. Manual mode allows you to adjust time and pressure settings. Program mode allows you to choose one of six programs that provide treatment for a set time then sleep (no treatment) for a set time, continuously, at a specif...

  • Page 12

    En-11 compression therapy (vasopneumatic compression) using the game ready system or any compression therapy device should not be used in patients: • who are in the acute stages of inflammatory phlebitis in the affected region. • who have any history or current clinical signs suggestive of deep vein...

  • Page 13

    En-12 • who are children under 18 years old or patients who have cognitive disabilities or communication barriers, whether temporary (due to medication) or permanent. • who have a cardiac insufficiency or congestive heart failure (with associated edema in the extremities or lungs). • who have a loca...

  • Page 14

    En-13 protection against electric shock: the game ready system is considered to be class i (protective earth) when connected to the ault model mw 128 power supply, and class ii (double insulated) when connected to the globtek model gtm-21097-5012 power supply. Protection against harmful ingress of w...

  • Page 15

    En-14 control unit the exterior of the control unit and the visible interior surfaces of the reservoir can be cleaned with a soft cloth and one of the following cleaning agents: • mild detergent • 70% isopropyl alcohol • 100% simple green® • quaternary ammonium (such as virex® – typically only found...

  • Page 16

    En-15 c l e a n i n g m a i n t e n a n c e s t o r a g e inspect and clean or replace the ice box filter as necessary. Remove the filter by rotating it counter-clockwise. No product maintenance should be performed by the user. If your game ready system requires maintenance, please contact game read...

  • Page 17

    En-16 a c c e s s o r i e s the game ready control unit can be used with any of the following accessories: • any game ready wrap. Wraps made by any other manufacturer cannot be used with this system. • a game ready supplied power supply (ault model mw128 or globtek model gtm-21097-5012) and hospital...

  • Page 18

    En-17 error what does it mean? What can i do? Air pressure sensor: the control unit has detected a problem calibrating the pneumatic compression circuit on start-up. • this is most likely to occur if you have restarted the system with an inflated wrap attached. • detach the wrap and try again. Self-...

  • Page 19

    En-18 error what does it mean? What can i do? Under pressure: the control unit can’t reach its target maximum compression. This often indicates that there is a leak in the pneumatic compression circuit, either in the connector hose, wrap or control unit. Or it may occur because the hook and loop fas...

  • Page 20

    En-19 coolsystems warrants that the game ready control unit, if properly used, will be free from defects in material and workmanship for a period of one (1) year after the date the game ready control unit was purchased. If the game ready control unit, which is the subject of this limited warranty, f...

  • Page 21

    En-20 ec rep emergo europe molenstraat 15 2513 bh, the hague the netherlands 0086 limitations of liability coolsystems’ responsibility under this, or any other warranty, implied or express, is limited to repair or replacement, as set forth above. These remedies are the sole and exclusive remedies fo...

  • Page 22

    Game ready control unit user’s manual pn 702742 rev h ©2013 coolsystems, inc. All rights reserved. Brought to you by coolsystems, inc. 1800 sutter street, suite 500 concord, ca 94520 1.888.Gameready (1.888.426.3732) +1.510.868.2100 www.Gameready.Com.