Gamma Scale Sartorius PMA 35D-X Nstallation And Operating Instructions

Manual is about: Electronic Paint-Mixing Scales

Summary of Sartorius PMA 35D-X

  • Page 1

    98648-008-38 sartorius pma 35d-x, pma 35d-x00c , pma 35d-x00cv1 electronic paint-mixing scales installation and operating instructions.

  • Page 2

    2 pma 35d-x, pma 35d-x000c, pma 35d-x00cv1 1 load plate 2 e key (on/off) 3 y correction key: decrease (only on the pma 35d-x00c and pma35d-x00cv) 4 = tare key 5 display 6 w key (toggle) on the 35d-x/35d- x00c, you can toggle to two decimal places – from 0.5 g to 1.0 g – within the entire weighing ra...

  • Page 3

    3 getting started remove the scale, load plate and ac adapter from the package. Immediately after unpacking the equipment, check it for any visible damage. Equipment supplied: scale, load plate, ac adapter, data cable (25-pin - 9-pin) do not miss out on the benefits of our full warranty. Please cont...

  • Page 4

    4 connect the scale to ac power. Install the power cable and grounding cable with adequate protection so that they cannot be damaged. Remove the load plate. Use a 13-mm open-end wrench to loosen the leveling foot (1). Turn the leveling foot (2) until the scale is level. Tighten the lock nut (1) with...

  • Page 5

    5 weighing with one decimal place place an empty paint can on the load plate (1). Press = (4). The display shows “0.0 g.” pour in the first component, and read off the weight as soon as the stability symbol appears; in this case, “g.” pour in additional components until the desired weight of your fo...

  • Page 6

    6 example: let’s suppose you want to weigh only 250 l of a basic formula for a total amount of 1 l. With the recalculation mode, you do not need to manually recalculate the individual components. The basic formula for 1 liter is: 250 g green paint + 250 g red paint + 500 g blue paint total: 1000 g 1...

  • Page 7

    7 15. Fill to 0.0 g. 0.0 g 14. Pour in the 2nd component; “c2” flashes on the display. – 2.0 g 13. Press the [mem] key (9) st 01 example: 1. Place an empty paint can on the load plate (1). + 118.0 g 2. Press the = key (4). 0.0 g 3. Pour in the 1st component. + 50.0 g 4. Press the [mem] key (9). St 0...

  • Page 8

    8 accessing the menu press e (2) to turn off the scale. Press e again to turn the scale back on; briefly press the = key (4) during the automatic self-test. “i “ is now displayed. Set the desired code as follows: press = (4) until the desired number is displayed. Press w (6); the middle number appea...

  • Page 9

    9 troubleshooting guide problem causes solution no segments appear – no ac power available – check the ac power supply on the weight display the display shows “l” – the load plate is not in place – position the load plate the display shows “h” – the load on the pan exceeds – unload the scale the sca...

  • Page 10

    10 specifications model pma 35d-x pma35d-x000c weight range kg 35 35 readability g 0.5/1 0.5/1 tare range (subtractive) kg – 35 – 35 max. Overload capacity kg 70 70 max. Linearity g repeatability 1 1 sensitivity drift 1/k at + 10° c to 30° c integration time, can be selected externally s 1.6 to 6.4 ...

  • Page 11

    11.

  • Page 12

    12.

  • Page 13

    13.

  • Page 14

    14.

  • Page 15

    15.

  • Page 16

    Sartorius ag 37070 goettingen, germany weender landstrasse 94 - 108, 37075 goettingen, germany copyright by sartorius ag, goettingen, germany. All rights reserved. No part of this publication may be reprinted or translated in any form or by any means without the prior written permission of sartorius...