Gardena 19080 Operating Instructions Manual

Manual is about: smart Pressure Pump

Summary of 19080

  • Page 1

    Art. 19080 reset slo cz pl i n fi dk s nl f gb d d betriebsanleitung smart pressure pump gb operating instructions smart pressure pump f mode d’emploi smart pressure pump i istruzioni per l’uso smart pressure pump nl gebruiksaanwijzing smart pressure pump s bruksanvisning smart tryckpump n bruksanvi...

  • Page 2: Gardena Smart Pressure Pump

    Gardena smart pressure pump contents: 1. Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15 2. Safety . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16 3. Installation . . . . . ...

  • Page 3: 2. Safety

    Reset l1 l2 l3 ß l3 power­led • green: power on • off: power off reset button • press briefly: new connection • press and hold (min. 5 seconds): cancels the existing connection and allows a new connection to be established, e.G. Different gateway pressure intensification: if you use the pump for pre...

  • Page 4

    V if the supply cord is damaged, it must be replaced by the manufacturer, its service agent or similarly qualified persons in order to avoid a hazard. According to din vde (german electrical engineers’ association) 0620, mains power cables and extension cables must not have a smaller cross-section t...

  • Page 5: 3. Installation

    3. Installation before you do installation: warning! Electric shock! Risk of injury due to electric shock. V disconnect the product from the mains before you do installation. Installation location: the pump must be installed in a location with an air humidity of it must be at a distance of at least ...

  • Page 6: 4. Operation

    Art. 1723 / art. 1724 2 3 4 particularly important for fixed installation: • for greater suction heads, use a suction hose with a small diameter (3/4"). 1. Put the suction hose fitting 3 on the suction inlet 4 . 2. Tighten the suction hose fitting 3 by hand. 3. Connect the suction hose 2 to the suct...

  • Page 7

    Factory reset: reset l1 l2 l3 the smart pressure pump will be reset to the factory settings. 1. Push and hold down the reset key for at least 5 seconds. To start the pump: 0 q 9 s l3 0 9 q a 1. Loosen the lid 9 of the filter chamber with the spanner 0 provided. 2. Slowly fill in the liquid to be pum...

  • Page 8: 5. Maintenance

    5. Maintenance before you do maintenance: warning! Electric shock! Risk of injury due to electric shock. V disconnect the product from the mains before you do maintenance. The gardena smart pressure pump should not require regular maintenance. To clean the filter: 0 9 q w 1. If necessary, close all ...

  • Page 9: 7. Troubleshooting

    Disposal: (in accordance with rl2012/19/ec) the product must not be added to normal household waste. It must be disposed of in line with local environmental regulations. Important! Make sure that the product is discarded through or via your municipal recycling collection centre. 7. Troubleshooting b...

  • Page 10

    Error­led ß l1 : reset l1 l2 l3 in the case of an error, the error-led ß l1 shows the corresponding disturbance states through various flashing frequencies, each with a 2 second break. Error­led flashes 1 time problem with the initial operation (in case of an error, led ß l1 flashes 30 seconds after...

  • Page 11

    Problem possible cause remedy error­led flashes 2 times. During the initial operation, the pump did not suck water for 6 minutes. Pump does not suck water problem on the suction side. V immerse suction hose end under water, v eliminate any leak on the suction side, v clean check valve on the suction...

  • Page 12: 8. Technical Data

    Problem possible cause remedy error­led flashes 4 times. The pump switches off during on-going operation after 60 minutes or 2 minutes. Leakage warning is activated leak on pressure side (e. G. Dripping tap). V eliminate any leak on the pressure side. Exceeded maximum duration (60 mins.) of the low ...

  • Page 13: 9. Accessories

    Smart pressure pump art. 19080 weight: 13.4 kg dimensions (l x w x h) 47 x 26 x 34 cm sound power level l wa 1) measured / guaranteed uncertainty k wa 77 db (a) / 79 db (a) 2.19 db (a) measuring process complying with 1) rl 2000/14/ec 9. Accessories gardena suction hoses kink and vacuum-resistant, s...

  • Page 14

    Leistungskurve: performance curve: courbe de performances : curva di rendimento: prestatiegrafiek: kapacitetskurva: ytelseskurve: suorituskykykäyrä: ydelseskurve: křivka výkonnosti: krivulja zmogljivosti: wykres wydajności: 0 5 10 0 50 100 bar m 0 5000 l/h 3000 1000 151.

  • Page 15

    D produkthaftung wir weisen ausdrücklich darauf hin, dass wir in Übereinstimmung mit dem produkthaftungsgesetz nicht für schäden haften, die durch unsere erzeugnisse entstehen, wenn diese unsachgemäß repariert wurden oder wenn keine originalteile von gardena oder zugelassene teile verwendet wurden, ...

  • Page 16

    D eu­konformitätserklärung der unterzeichnete husqvarna ab, 561 82 huskvarna, sweden bestätigt, dass die nachfolgend bezeichneten geräte in der von uns in verkehr gebrachten ausführung die anforderungen der harmo nisierten eu-richtlinien, eu-sicherheitsstandards und produktspezifischen standards erf...

  • Page 17

    Produktbeschreibung: description of the product: désignation du produit : descrizione del prodotto: beschrijving van het product: beskrivning av produkten: tuotteen kuvaus: beskrivelse af produktet: popis výrobku: opis izdelka: opis produktu: eu­richtlinien: ec­directives: directives ce : direttive ...

  • Page 18

    92 deutschland / germany gardena manufacturing gmbh central service hans-lorenser-straße 40 d-89079 ulm produktfragen: (+49) 731 490- 123 reparaturen: (+49) 731 490- 290 service @ gardena.Com albania cobalt sh.P.K. Rr. Siri kodra 1000 tirana argentina husqvarna argentina s.A. Av.Del libertador 5954 ...