Gardena 19080 Operating Instructions Manual - page 11
Problem
Possible Cause
Remedy
ErrorLED flashes 2 times.
During the initial operation,
the pump did not suck water
for 6 minutes.
Pump does not suck water
Problem on the suction side.
v
Immerse suction hose end
under water,
v
eliminate any leak on the
suction side,
v
clean check valve on the
suction line and check
the installation direction,
v
clean suction filter on the
suction hose end,
v
clean filter lid seal and turn
lid until the stopper
(see 5. MAINTENANCE),
v
clean the filter in the pump.
Suction hose deformed or bent.
v
Use a new suction hose.
Pump does not start
The thermal circuit breaker
has been activated
(motor overheated).
v
Let the pump cool down for
20 min.
ErrorLED flashes 3 times.
During the current operation,
the pump did not suck water
for 30 seconds.
Water supply disrupted
on the suction side
Problem on the suction side.
v
Immerse suction hose end
under water,
v
eliminate any leak on the
suction side,
v
clean check valve on the
suction line and check
the installation direction,
v
clean suction filter on the
suction hose end,
v
clean filter lid seal and turn
lid until the stopper
(see 5. MAINTENANCE),
v
clean the filter in the pump.
Suction hose deformed or bent.
v
Use a new suction hose.
Pump does not start
The thermal circuit breaker
has been activated
(motor overheated).
v
Let the pump cool down
for 20 min.
Flow Sensor signal is faulty
Flow Sensor is blocked.
v
Clean the flow sensor
(see To clean the flow sensor).
24