The ionosphere data are stored in Iono DB by using the SBAS Iono Correction module to elaborate the SBAS
message. The data related to the satellite correction (fast/slow/clock correction) are elaborated by the SBAS
Satellite Correction module and then stored in Satellite DB.
Every 30 seconds the Correction Generator module gets data from the database and elaborates them to provide
the total correction for every GPS satellite by using a GPS library function.
10.1
Available SBAS Satellites
In WAAS system region, (USA, Canada and Mexico)
122 for Inmarsat 3F4 AOR-W 54.0
West
http://www.lyngsat.com/tracker/inmar3f4.shtml
134 for Inmarsat 3F3 POR 178.0
East
http://www.lyngsat.com/tracker/inmar3f3.shtml
In EGNOS system region (Europe and Africa)
120 for Inmarsat 3F2 AOR-E 15.5
West
http://www.lyngsat.com/tracker/inmar3f2.shtml
124 for Artemis 21.5
East
http://www.lyngsat.com/tracker/artemis.shtml
126 for Inmarsat 3F5 IOR-W 25.0
East
http://www.lyngsat.com/tracker/inmar3f5.shtml
In MSAS system region (Japan, Australia and Hawaii)
129 for MTSAT 1
137 for MTSAT 2