ICentral System One M200 Installation Manual - page 21
17
17
INSTALLATION OF K200 (S1DT) DESKTOP STATION
The desktop station connects to a wall plate by means of a CAT5 Patch Lead (RJ45 to RJ45)
The patch lead should be “straight through” and not “crossover” in that the wire colour coding
should be the same at both ends of the lead.
The wall plate used is to be fitted with a CAT5 IDC Jack marked with T568A colour coding.
(Many CAT5 IDC Jacks have both T568A and T568B colour coding and are marked by A or B
respectively)
The CAT5 cable from the master wires to the CAT5 IDC connector according to the T568A colour
coding standard.
The pin numbering for the RJ45 jack on the wall plate and on the Desktop Station
is as per this drawing.
Using the recommended straight through patch lead, the cable functions are as
follows:
Please note that the IDC connections on
the RJ45 wall plate jack are designed to
work best with solid core CAT5 cable.
The use of stranded CAT5 cable however
is recommend for making up patch leads.
PIN FUNCTION
WALL PLATE
CONNECTIONS (T568A)
1
POS
GREEN/WHITE
2
NEG
GREEN
3
TC
ORANGE/WHITE
4
COM2
BLUE
5
COM1
BLUE/WHITE
6
VLC
ORANGE
7
MUS1
BROWN/WHITE
8
MUS2
BROWN