ICentral System One M200 Installation Manual - page 32
28
28
INITIAL POWERUP
On powerup the master displays a blue welcome screen showing the applicable software version.
Press CLEAR to clear screen
ENTERING PROGRAM MODE
Press PRIV and MON buttons simultaneously.
The GENERAL OPTIONS menu is displayed.
NAVIGATING IN PROGRAM MODE
Press or buttons to navigate up or down.
Press or ⊳ to alter value
Use PREV/NEXT MENU to navigate between menus
GENERAL OPTIONS MENU
– 8 WIRE is the default setting however 6 WIRE can be selected to cater for
existing cabling having only 6 conductors
Note: For 6 wire operation, wire links are required between COM1 and MUS1 and between COM2 and MUS2
at master only.
– Options are OFF, LOW, MEDIUM & HIGH with medium being the default value
– Refers to how many buttons need to be pressed to call individual
stations. SINGLE DIGIT is the default setting and is the most convenient setting for calling up to 7
individual stations (or 7 groups of stations). The double digit setting is required for systems where
more than 7 stations are to be called individually.
Note: Master and all room stations are to be programmed to the same setting.
– Master can be programmed from 1 to 7 (single digit)
or 11 to 17, 21 to 27, 31 to 37 (double digit)
Note: The number 8 is normally reserved for activation of lock release feature and is not used for station numbering.
STATION OPTIONS MENU
– ADDITIONAL DISPLAY is the default setting
and should be used where extra display(s) are connected via the VIDEO OUT terminals. The
VIDEO ROOM STN setting changes the way the Video Out Switched 12V operates and is
intended for use with video room stations (to be released in the future).
– Sets the number of door stations that have an inbuilt or associated external
camera. Options are 1, 2 or 3. If “1 CAM DOOR STN” is selected, door station No.1 (wired to
VLC1) will be the door station with the camera.
If “2 CAM DOOR STN” is selected, door stations 1 & 2 (wired to VLC1 and VLC2) will be the
door stations with cameras.