REQUIRED TEST EQUIPMENT
Note:
[MPT] versions must use ‘
CS-F600
’ instead of ‘
CS-F500
’.
5-1 PREPARATION
When you adjust the contents on pages 5-4 and 5-5, SOFT-
WARE ADJUSTMENT, the optional CS-F500 ADJ
ADJUSTMENT
SOFTWARE
(Rev. 1.0 or later), *OPC-1122
JIG CABLE
(modified
OPC-1122
CLONING CABLE
; see illustration below) are required.
■
SYSTEM REQUIREMENTS
• IBM PC compatible computer with an RS -232C serial port
(38400 bps or faster)
• Microsoft Windows 95/98 or Windows ME
• Intel Pentium 100 MHz processor or faster
• At least 16 MB RAM and 10 MB of hard disk space
• 640
×
480 pixel display (800
×
600 pixel display recommended)
■
ADJUSTMENT SOFTWARE INSTALLATION
q
Boot up Windows.
- Quit all applications when Windows is running.
w
Insert the ‘CS-F500’ into the appropriate CD-ROM drive.
e
Select ‘Run’ from the [Start] menu.
r
Type the setup program name using the full path name,
then push [Enter] key.
(ex. D:\CSF500ADJ\disk1\Setup.exe)
t
Follow the prompts.
y
Program group ‘CS-F500 ADJ’ appears in the ‘Programs’
folder of the [Start] menu.
■
STARTING SOFTWARE ADJUSTMENT
q
Connect IC-F610, F620 or F621 and PC with *OPC-1122
JIG CABLE
.
w
Turn the transceiver power ON.
e
Boot up Windows, and click the program group ‘CS-F500
ADJ’ in the ‘Programs’ folder of the [Start] menu, then
CS-F500 ADJ’s window appears.
r
Click ‘Connect’ on the CS-F500’s window, then appears
IC-F610, F620 or F621’s up-to-date condition.
t
Set or modify adjustment data as desired.
5 - 1
EQUIPMENT
DC power supply
RF power meter
(terminated type)
Frequency counter
FM deviation meter
DC voltmeter
GRADE AND RANGE
Output voltage
: 13.2 (13.6) V DC
Current capacity
: 20 A or more
Measuring range
: 1–75 W
Frequency range
: 300–600 MHz
Impedance
: 50
Ω
SWR
: Less than 1.2 : 1
Frequency range
: 0.1–600 MHz
Frequency accuracy : ±1 ppm or better
Sensitivity
: 100 mV or better
Frequency range
: DC–600 MHz
Measuring range
: 0 to ±10 kHz
Input impedance
: 50 k
Ω
/V DC or better
EQUIPMENT
Audio generator
Standard signal
generator (SSG)
Oscilloscope
AC millivoltmeter
External speaker
Attenuator
GRADE AND RANGE
Frequency range
: 300–3000 Hz
Measuring range
: 1–500 mV
Frequency range
: 0.1–600 MHz
Output level
: 0.1 µV–32 mV
(–127 to –17 dBm)
Frequency range
: DC–20 MHz
Measuring range
: 0.01–20 V
Measuring range
: 10 mV–10 V
Input impedance
: 4
Ω
Capacity
: 7 W or more
Power attenuation
: 50 or 60 dB
Capacity
: 100 W or more
SECTION 5
ADJUSTMENT PROCEDURES
+
Audio generator
300 Hz to 3 kHz
AC
millivoltmeter
MICE
MIC
PTT
PTT switch
PTTE
Add a jumper wire here
• *OPC-1122 (JIG CABLE)
Electrolytic
capacitor
47
µ
F
OPC-1122
(Cloning cable)
IBM is a registered trademark of International Bussiness
Machines Corporation in the U.S.A. and other countries.
Microsoft and Windows are registered trademarks of
Microsoft Corporation in the U.S.A. and other countries.
Screen shots produced with permission from Microsoft
Corporation. All other products or brands are registered
trademarks or trademarks of their respective holders.