Icom IC-FR5100 Instruction Manual - Power Supply Connection
7
2
INSTALLATION AND CONNECTIONS
■
Power supply connection
Make sure the repeater’s power is turned OFF when
connecting a DC power cable.
CAUTION: Voltages greater than 16 V DC will dam-
age the repeater. Check the source voltage before
connecting the power cable.
■
Mounting the repeater
D
Using the supplied handle
The supplied handles are useful when mounting the
repeater into a 19 inch rack. The handles are installed
on the repeater’s front panel.
q
Attach the supplied handles to both sides of the re-
peater’s front panel with the spacers, then tighten
the screws as shown below.
P0
P1
P2
P3
P4
Handle
Spacer
Screw
w
The completed installation should look like this.
P0
P1
P2
P3
P4
■
Rear panel connection— For the IC-FR5100/IC-FR6100
CAUTION: NEVER
remove the
fuse holders from the DC power
receptacle.
EXTERNAL SPEAKER
4
˘
external speaker
Connects to a TX antenna
(p. 5)
Connects to an
RX antenna (p. 5)
ACC CONNECTOR
(p. 3)
Used for external
equipment control.
Connects to a dPMR
control unit, if used.
Black
Red
20 A
fuses
DC power supply
AC outlet
AC cable
Supplied
DC power cable
13.2 V; at least 15 A
Black
_
Red
+
R
When you disconnect the DC power cable, take
care to not break your fingernail.
q
Push
w
NOTE: The optional UR-PA5000/UR-PA6000
power
amplifier
units
can be installed. See
the installation guide that comes with the
UR-PA5000/UR-PA6000 for details.