TRX2
TRX3
IN
+
+
+
OUT
SW
ABC
MODE
DC
LAN
TRX1
TRX2
TRX3
IN
+
+
+
OUT
SW
ABC
Multicast mode connection example
[Area A]
[Area B]
IP
network
VE-PG2
192.168.0.1
VE-PG2
192.168.0.2
Connect the transceiver to the
VE-PG2’s [TRX1] port.
Connect the transceiver to the
VE-PG2’s [TRX1] port.
CAUTION:
To connect the transceivers or repeaters, use only the following cables: OPC-2073 (For the transceivers) or
OPC-2074 (For the repeaters).
Using another cable, like an Ethernet cable, may damage the VE-PG2, transceivers or repeaters.
Click “Next>>” when “Start the Easy Setup Wizard for
Bridge mode configuration” is displayed on the web
browser.
Enter the VE-PG2’s IP address and subnet mask in “IP
address” and “Subnet mask.”
• Set the default gateway when your VE-PG2 communicates with a
network device which has a different network IP address.
Click “Next>>”after you finish entering the VE-PG2’s IP
address and subnet mask.
Select “Multicast mode” in “IP communication mode setting,”
then click “Next>>.”
Confirm the VE-PG2 settings at “Verify setting,” then Click
“Save and Reboot” to set the settings to the VE-PG2.
• If you want to change the VE-PG2’s settings, click “< Confirm that the VE-PG2’s “Operating mode” is set to “Bridge mode” in “Operating mode setting.” • Default setting is “Bridge mode.” When you click “Begin wizard,” the VE-PG2 starts the setting wizard. Set the VE-PG2’s “Operating mode” to “Selective call mode” in “Operating mode setting,” then click “Save and Reboot.” • To set the VE-PG2 to the multicast mode, see “When you set the VE-PG2 to the bridge mode (multicast mode),” as shown below. • To set the VE-PG2 to the unicast mode, see “When you set the VE-PG2 to the bridge mode (Unicast mode),” as shown on the reverse side. To set the VE-PG2 to the selective call mode, see “When you set the VE-PG2 to the selective call mode,” as shown on the reverse side. Click “switch to the easy configuration mode” in the “Setting mode,” then the VE-PG2 is set to the easy configuration wizard. This explanation describes how you set the VE-PG2 to the bridge mode (multicast mode) using the easy configuration wizard with the connection shown below. “Change operating mode” When you click “Switch to detailed configuration mode,” the VE-PG2 is set to the detailed configuration mode. “Operating mode setting” You can change or confirm the VE-PG2’s operating mode. Select the operating mode, and then click “Save and Reboot,” to change the operating mode. “Config Wizard” When you click “Begin wizard,” the VE-PG2 starts the easy configuration wizard. “Connection setting” You can change or confirm the VE-PG2’s settings. If you click “Save and Reboot,” the VE-PG2 registers the settings after the reboot is completed. • You can change the VE-PG2’s settings in both the bridge mode and the converter mode. “Cancel”/“Save and Reboot” buttons You can cancel the VE-PG2’s setting by clicking “Cancel.” When you click “Save and Reboot,” the VE-PG2 registers the settings after the reboot is completed. • The setting screen is the VE-PG2’s setting display in Area A. This guide describes the easy configuration wizard of “Bridge mode” and “Selective call mode,” and includes a connection example. When you use only the [TRX1] port, you can easily setup the VE-PG2 using the easy configuration wizard. Read “ PRECAUTIONS” first, if you have not read it. Read this guide after reading “Installation guide q” for the transceiver settings. NOTE: • To set the VE-PG2 to “Converter mode,” see “Converter mode guide” for that mode’s explanation and setting details after reading below “1. Select the VE-PG2 to the easy configuration wizard” for the easy configuration wizard screen explanation. • Connect the transceiver to only the VE-PG2’s [TRX1] port. You cannot set the VE-PG2’s [TRX2] and [TRX3] ports using the easy configuration wizard. • Set the SIP server’s setting first when you set the VE-PG2 to the converter mode. The easy configuration can set the VE-PG2 only to SIP server sending. To set the VE-PG2 to Peer to Peer sending, use the detail setting mode. • To connect the transceiver to VE-PG2’s [TRX2] and [TRX3] ports, use the detail setting mode. To set the VE-PG2’s external input or external output to ON, use the detail setting mode. 1. Select the VE-PG2 to the easy configuration wizard If you click “Switch to detailed configuration mode,” the VE-PG2 is set to the detail setting mode. When you switch from the VE-PG2’s “Easy configu- ration mode.” About the easy configuration wizard screen 2. Start the easy configuration wizard Sets the VE-PG2 to the Bridge mode Sets the VE-PG2 to the Selective call mode 1. Confirm the VE-PG2’s “Operating mode” 2. Start the configuration wizard 1. Set the VE-PG2’s “Operating mode” When you click “Begin wizard,” the VE-PG2 starts the setting wizard. 2. Start the configuration wizard NOTE: When you set the VE-PG2 to the Converter mode, see “Converter mode guide” for details. ‘ When you set the VE-PG2 to the bridge mode (multicast mode) 1. “IP Address setting” setting 2. “IP communication mode setting” setting 3. Confirm the VE-PG2 settings • The setting screen is the VE-PG2’s setting display in Area A. Click Click Confirm Click q Select w Click Click q Enter (Example) Enter “192.168.0.1” into the VE-PG2 in Area A, and “192.168.0.2” into the VE-PG2 in Area B in the illustration above. w Click q Select w Click q Confirm w Click