Intermec MaxiScan 3100 User Manual

Other manuals for MaxiScan 3100: Installation Manual, Installation Manual
Manual is about: Intermec MaxiScan 3010: User Guide

Summary of MaxiScan 3100

  • Page 1

    Fixed industrial scanner data book june1999 intermec data capture 1 the maxiscan 3000 series fixed industrial scanner data book david downey copyright 1999 intermec stc, toulouse france all rights reserved intermec recognises that all trade marks are the property of their respective owners.

  • Page 2: Intermec Data Capture

    Fixed industrial scanner data book june1999 intermec data capture 2 1.0. Introduction the maxiscan 3000 series scanners are industrial fixed scanners. The scanners are compact and ruggedised to operate in the following environments: in on performing this data book is designed to explain the many fea...

  • Page 3: Intermec Data Capture

    Fixed industrial scanner data book june1999 intermec data capture 3 2.0 maxiscan 3000 series key features features of the maxiscan range: • range of scanners for industrial applications • easyset software makes them simple to install • compact and rugged metal cases (ip65/nema12) • high performance ...

  • Page 4: Intermec Data Capture

    Fixed industrial scanner data book june1999 intermec data capture 4 3.0 application areas 3.1. Conveyor reading a primary application for the m3xxx is reading products on passing conveyors. The m3100st and m3300 are designed to be fixed to conveyors and to read codes in ladder or picket orientations...

  • Page 5: Intermec Data Capture

    Fixed industrial scanner data book june1999 intermec data capture 5 4.0 maxiscan 3000 series key features 4.1. Active line control (alc) – m3300 only the maxiscan 3300 is a multi-functional moving-beam bar code laser scanner providing line, raster and multi-directional scan patterns. The unique scan...

  • Page 6: Intermec Data Capture

    Fixed industrial scanner data book june1999 intermec data capture 6 • vertical scan lines vertical lines can be generated without needing to tilt the scanner. These are used for scanning ladder codes. • raster patterns the horizontal or vertical lines can be swept through angles of up to 30° to prod...

  • Page 7: Intermec Data Capture

    Fixed industrial scanner data book june1999 intermec data capture 7 applications often change. Alc allows the scan pattern to be changed to follow the new requirements without hardware updates. This can result in much lower running costs when compared to conventional scanners. Alc simplifies scanner...

  • Page 8: Intermec Data Capture

    Fixed industrial scanner data book june1999 intermec data capture 8 4.5 easyset system configuration software the configuration, testing and tuning of fixed scanners is simplified by intermec’s easyset, a windows based pc configuration software. Easyset is a unique tool that allows you to work off- ...

  • Page 9: Intermec Data Capture

    Fixed industrial scanner data book june1999 intermec data capture 9 5.0 fundamentals of fixed position scanning 5.1 the bar code the m3000 series is principally designed to read linear symbologies (bar codes). A linear bar code is a number of bars and spaces containing data arranged in parallel rows...

  • Page 10: Intermec Data Capture

    Fixed industrial scanner data book june1999 intermec data capture 10 3. Quiet zone. This clear area is required by the specification of most codes. For reliable reading this zone should be equal to 10 * the x dimension. Fig 5. The parts of a code (ean 13 code) • print quality 1. How is the code prin...

  • Page 11: Intermec Data Capture

    Fixed industrial scanner data book june1999 intermec data capture 11 5.3 orientation linear bar codes do not have significant error correction and therefore the scanning line must completely cover the bar code to achieve a successful scan. The size of the code, its aspect ratio (ratio of height to l...

  • Page 12: Intermec Data Capture

    Fixed industrial scanner data book june1999 intermec data capture 12 it is important to know how good the label placement is relative to the scanner. Each scanner has a spec for reading a label and the following terms are used to describe the position of the label relative to the scan: tilt can seve...

  • Page 13: Intermec Data Capture

    Fixed industrial scanner data book june1999 intermec data capture 13 a picket code and thus the number of scans per code can be very small. This has security problems (see section 7.4 on number of scans per code). The position of the label relative to the scanner causes similar effects to picket cod...

  • Page 14: Intermec Data Capture

    Fixed industrial scanner data book june1999 intermec data capture 14 for angled picket codes, the number of scans should be calculated by reducing the width of scan figure (ws) in proportion to the tilt angle. For ladder codes the formula is number of scans = (hc/cs x sr) - 2 where hc = height of co...

  • Page 15: Intermec Data Capture

    Fixed industrial scanner data book june1999 intermec data capture 15 6.0 intermec’s easyset system the m3000 series is supplied with a windows compatible configuration software package on cd-rom. This software makes the configuration easy to do and gives two options for communicating to the scanner:...

  • Page 16: Intermec Data Capture

    Fixed industrial scanner data book june1999 intermec data capture 16 a unique concatenation feature makes it possible for the set-up codes to be merged as one code that contains all the information to configure the scanner. This feature is especially useful if the sheet is to be used to set-up many ...

  • Page 17: Intermec Data Capture

    Fixed industrial scanner data book june1999 intermec data capture 17 6 .4 terminal function a terminal mode allows the scanner to send data to the pc so that configurations can be tested. The m3300 has a reading efficiency test allows the scanner to be tuned for maximum read rates. 6.5 m3300 set-up ...

  • Page 18: Intermec Data Capture

    Fixed industrial scanner data book june1999 intermec data capture 18 7.0 optimising an application 9.1. Scan line or pattern ensure that the scan line or pattern is best suited to the code. Hints for picket codes : if a single line is being used, tilt it slightly to allow it to see more of the bar-c...

  • Page 19: Intermec Data Capture

    Fixed industrial scanner data book june1999 intermec data capture 19 9.5 efficiency for the m3300 use the terminal efficiency reading in easyset to test the scanner, code and label set-ups. 9.6 input synchronisation wherever possible, an input trigger from a sensor (opto) should be used to turn the ...

  • Page 20: Intermec Data Capture

    Fixed industrial scanner data book june1999 intermec data capture 20 appendix a1. Application checklist a2. Technical characteristics & drawings a3. Connections and cables a4. Parts list.

  • Page 21: Intermec Data Capture

    Fixed industrial scanner data book june1999 intermec data capture 21 a1. Application checklist 1. Bar codes . Symbology(s) type(s) what is the orientation of the code ladder picket are there multiple codes on the same label yes number : no what is the code width and height width mm/ins height mm/ins...

  • Page 22: Intermec Data Capture

    Fixed industrial scanner data book june1999 intermec data capture 22 3. Environment area shopfloor warehouse ambient temperature range min max °c/ f average °c/f humidity %rh moisture/ dust ip nema proximity to other large machines m/ ft type note : it can be useful to use this section as an applica...

  • Page 23: Intermec Data Capture

    Fixed industrial scanner data book june1999 intermec data capture 23 a2 technical characteristics & drawings technical characteristics are subject to change without prior notice due to continuous product improvement. 0 dqg 0 6shflilfdwlrqv m3100 specification general the maxiscan 3100 is a range of ...

  • Page 24: Intermec Data Capture

    Fixed industrial scanner data book june1999 intermec data capture 24 m3300 specification general the maxiscan 3300 is a multi-functional moving beam bar code scanner for fixed applications. Models include m3300st and m3300hr ------------------------------------------------- physical characteristics ...

  • Page 25: Intermec Data Capture

    Fixed industrial scanner data book june1999 intermec data capture 25 dimensions m3100 56mm (2.2 in) 36mm (1.4 in) 75mm (2.9 in) 48mm (1.89in).

  • Page 26: Intermec Data Capture

    Fixed industrial scanner data book june1999 intermec data capture 26 38 mm (1.5") 14 mm (0.5") 75 mm (2.9") 100 mm (3.9") 82 mm (3.2") 30 mm (1.2") scale: ½.

  • Page 27: Intermec Data Capture

    Fixed industrial scanner data book june1999 intermec data capture 27 0d[l6fdq &rqqhfwlrq 6\vwhp h[whuqdo xqlw rswlrq 30 mm (1.18") 113 mm (4.45") 70 mm (2.76") scale: 1.

  • Page 28: Intermec Data Capture

    Fixed industrial scanner data book june1999 intermec data capture 28 0rxqwlqj srlqwv odvhu oljkw sodqh 100 mm (3.9") 82 mm (3.2") 38 mm (1.5") 30 mm (1.2") 75 mm (2.9") 14 mm (0.5") 30 ° 40 ° scale: ¼.

  • Page 29: Intermec Data Capture

    Fixed industrial scanner data book june1999 intermec data capture 29 2swlrqdo dgmxvwdeoh vwdqg 4 x m 4 5 mm (0.2") depth 4 x Ø 4 30 mm (1.18") 92.5 mm (3.64") 52 mm (2.01") 38 mm (1.5") 52 mm (2.01") scale:.

  • Page 30: Intermec Data Capture

    Fixed industrial scanner data book june1999 intermec data capture 30 horizontal scan width / reading distance / barcode density 1.0 m3100sr.

  • Page 31: Intermec Data Capture

    Fixed industrial scanner data book june1999 intermec data capture 31 067.

  • Page 32: Intermec Data Capture

    Fixed industrial scanner data book june1999 intermec data capture 32 67 the values shown are for high-contrast code 39 with a ratio of 1:3 and correspond to the product default settings..

  • Page 33: Intermec Data Capture

    Fixed industrial scanner data book june1999 intermec data capture 33 horizontal scan width / reading distance / barcode density +5 the values shown are for high-contrast code 39 with a ratio of 1:3 and correspond to the product default settings..

  • Page 34: Intermec Data Capture

    Fixed industrial scanner data book june1999 intermec data capture 34 a3 connections and cables m3100 connection options 1 y cable 2 mcs box power y cable part no.0-530062-02 mcs pn. 0-531029-06 power supply synchro pn. 3-500029-03 host cable pn. 0-530062-01.

  • Page 35: Intermec Data Capture

    Fixed industrial scanner data book june1999 intermec data capture 35 maxiscan 3300 connection options 1 y cable 2 mcs box power y cable part no.0-530062-02 power supply mcs pn. 0-531029-06 synchro pn. 3-500029-03 host cable pn. 0-530062-01.

  • Page 36: Intermec Data Capture

    Fixed industrial scanner data book june1999 intermec data capture 36 m3100 cable output.

  • Page 37: Intermec Data Capture

    Fixed industrial scanner data book june1999 intermec data capture 37 m3100 cable converter cable (to 422/485) pn 3-510022-00

  • Page 38: Intermec Data Capture

    Fixed industrial scanner data book june1999 intermec data capture 38 m3300 cable connector 7-25 gnd gnd 7-25 vdc vdc so- so+ si- si+ rts cts tx rx rs-232 c tx+ rx+ tx- rx- rs-422 / 485 nc shield nc 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 both 7-25 vdc power supply pins must be powered both gnd pins must...

  • Page 39: Intermec Data Capture

    Fixed industrial scanner data book june1999 intermec data capture 39 rs-232 c 7-25 gnd gnd 7-25 vdc vdc so- so+ si- si+ rts cts tx rx nc shield nc 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 both 7-25 vdc power supply pins must be pow ered both gnd pins must be used i/o sync max current 50 ma slq vxe' ihpdo...

  • Page 40: Intermec Data Capture

    Fixed industrial scanner data book june1999 intermec data capture 40 rs-422 9 10 11 12 13 14 15 1 2 3 4 5 6 7 8 rs-422: install resistor = 100 ohm 7-25 gnd gnd 7-25 vdc vdc so- so+ si- si+ tx+ rx+ tx- rx- nc shield nc 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 host male subd cable connector both 7-25 vdc p...

  • Page 41: Intermec Data Capture

    Fixed industrial scanner data book june1999 intermec data capture 41 rs-485 rs-485: connect pins 1 and 2 and connect pins 3 and 4 install resistor = 120 ohm between pins 1 and 3 9 10 11 12 13 14 15 1 2 3 4 5 6 7 8 7-25 gnd gnd 7-25 vdc vdc so- so+ si- si+ tx+ rx+ tx- rx- nc shield nc 15 14 13 12 11 ...

  • Page 42: Intermec Data Capture

    Fixed industrial scanner data book june1999 intermec data capture 42 maxiscan connection system (mcs) option port type connection remarks scanner 15-pin subd male - power supply 7-25 v 9-pin subd male external power supply 7-25 v 10 watt full-wave rectified unregulated power host 15-pin subd female ...

  • Page 43: Intermec Data Capture

    Fixed industrial scanner data book june1999 intermec data capture 43 scanner port 7-25 vdc pwr gnd 7-25 vdc chassis gnd 9 10 11 12 13 14 15 1 2 3 4 5 6 7 8 si+ si- so+ so- rs-232 c rx tx cts rts rs-422 / 485 rx- tx- rx+ tx+ slq vxe' pdoh frqqhfwru pin function 1 receive data (rs-232 c) / rx- (rs-422...

  • Page 44: Intermec Data Capture

    Fixed industrial scanner data book june1999 intermec data capture 44 power supply 7-25v port 6 7 8 9 1 2 3 4 5 gnd (2 wires) 7-25 vdc (2 wires) slq vxe' pdoh frqqhfwru pin function 1 power in (7 to 25 vdc 10 watt unregulated) 2 power in (7 to 25 vdc 10 watt unregulated) 3 not connected 4 not connect...

  • Page 45: Intermec Data Capture

    Fixed industrial scanner data book june1999 intermec data capture 45 host port—rs-232 c rts cts tx rx gnd 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0&6 slq vxe' ihpdoh frqqhfwru pin function 1 receive data (rs-232 c) 2 transmit data (rs-232 c) 3 clear to send (rs-232 c) 4 request to send (rs-232 c) 5 not ...

  • Page 46: Intermec Data Capture

    Fixed industrial scanner data book june1999 intermec data capture 46 host port—rs-422 (use converter cable for m3100) 9 10 11 12 13 14 15 1 2 3 4 5 6 7 8 tx+ rx+ tx- rx- gnd 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 rs-422: install resistor = 100 ohm host male subd cable connector 0&6 slq vxe' ihpdoh frqq...

  • Page 47: Intermec Data Capture

    Fixed industrial scanner data book june1999 intermec data capture 47 host port—rs-485 (use converter cable for m3100) rs-485: connect pins 1 and 2 and connect pins 3 and 4 install resistor = 120 ohm between pins 1 and 3 9 10 11 12 13 14 15 1 2 3 4 5 6 7 8 tx+ rx+ tx- rx- gnd 15 14 13 12 11 10 9 8 7 ...

  • Page 48: Intermec Data Capture

    Fixed industrial scanner data book june1999 intermec data capture 48 host port—current loop (passive type) rx- rx+ tx- tx+ 9 10 11 12 13 14 15 1 2 3 4 5 6 7 8 gnd 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 host male subd cable connector current loop: connect pins 1 and 10 0&6 slq vxe' ihpdoh frqqhfwru pin ...

  • Page 49: Intermec Data Capture

    Fixed industrial scanner data book june1999 intermec data capture 49 synchros port in all cases, the synchronization current provided by the external input/output device must be limited to 50 ma max (20 ma is a good average value). 9 8 7 6 5 4 3 2 1 si- si+ so- so+ +5v 7-25v pwr gnd slq vxe' ihpdoh ...

  • Page 50: Intermec Data Capture

    Fixed industrial scanner data book june1999 intermec data capture 50 standard rs-232 c cable gnd 9 8 7 6 5 4 3 2 1 9 10 11 12 13 14 15 1 2 3 4 5 6 7 8 rx tx cts rts rs-232 c shielded cable (shielding connected to casing of cable connectors) cable connector - 15-pin subd male maxiscan connexion syste...

  • Page 51: Intermec Data Capture

    Fixed industrial scanner data book june1999 intermec data capture 51 a4. Parts list for m3000 series ordering number product description maxiscan 3100 sr (short range) type: fixed industrial linear ccd scanner, scan rate: 400 nom. 800 max scans/second. Reading distance: 0-10cm(0-4"), symbologies: 1d...

  • Page 52: Intermec Data Capture

    Fixed industrial scanner data book june1999 intermec data capture 52 maxiscan 3300 standard range, kits with mcs boxes and power units. Includes: rs 232 /422/485 scanner w. Thermo-cooler, fixed cable, mcs connection box, power unit, install guide and cd (with easyset). 0-531052-13 standard range kit...

  • Page 53: Intermec Data Capture

    Fixed industrial scanner data book june1999 intermec data capture 53 0-900029-01 cd rom (in kit packs as standard) 3-510029-00 mounting bracket, m3100 only - metal for horiz. & vert. Surfaces 0-531029-05 adjustable stand - m3100 & m3300 3-500029-03 optical package sensor for input synchro, connects ...