Model Number, etc., is provided on this plate. Should the type of gas need change in the field,
PLEASE inform the manufacturer at once. Experienced responsible service personnel only
should convert the appliances from one type of gas to another type (Natural/Propane only). The
regulator, burners orifices, pilot orifices, and rating plate description must be changed.
Use quality pipe compound on all pipe joints. This compound must be resistant to the action of
liquefied petroleum gases.
UPON CONNECTION, IMMEDIATELY LEAK TEST ALL PIPING AND CONNECTIONS UP TO
THE INLET OF THE SAFETY VALVE. THIS APPLIANCE IS EQUIPPED WITH A 100%
SAFETY SHUT-OFF VALVE SO THE PILOT MUST BE LIT TO CHECK CONNECTIONS
DOWNSTREAM OF THE SAFETY VALVE; SEE “LIGHTING INSTRUCTIONS.” THE MAIN
BURNERS MUST BE ON TO CHECK MAIN BURNER TUBING CONNECTIONS.
LIGHTING INSTRUCTIONS
When all electrical and gas connections are approved and the appliance is ready for operation,
proceed as follows:
1. Turn main gas valve to the appliance “ON.”
2. Turn both burner valves “OFF.”
3. Remove service panel.
4. Push red button on safety pilot and light pilot. Continue to push red button until pilot
remains lit when button is released. Replace service panel.
5. Burners can now be operated. If pilot is extinguished, repeat Steps 2 through 4.
Allow 5 minutes to elapse before attempting to re-light a unit that has been in operation
previously.
OPERATION
1. Open the door and turn the power switch “ON.” The red light indicates that there is power to
the motor control – See Figure 2.
All gas connections must be checked for leaks using a soap and water
solution. DO NOT USE AN OPEN FLAME FOR CHECKING PURPOSES.
This appliance and its individual shut-off valve must be disconnected from the gas
supply piping system during any pressure testing of that system at test pressures in
excess of ½ psig (3.45 kPa). The appliance must be isolated from the gas supply piping
system by closing its individual manual shut-off valve during any pressure testing of the
gas supply piping system at test pressure equal to or less than ½ psig (3.45 kPa).