Jade JTRG Series Installation, Operation And Maintenance Instructions - page 6
P/N 24-127 REV A 7/00
Page 6
2. Rotate the REVOLUTION CONTROL knob to the desired speed. The green light indicates
power to the drive motor. TURN THE REVOLUTION CONTROL KNOB SLOWLY; rapid
speed changes can result in unsafe conditions, blown fuses, or equipment damage.
3. Turn the burner knobs on and heat to the desired temperature. Do not overheat the griddle.
Low heat can be obtained by using only one burner at its low setting. The plate should be
revolving when the burners are operating.
4. To shut down, turn both knobs to the “OFF” position and turn the power switch “OFF.” To
extinguish the pilot, close the installer supplied shutoff valve.
USE AND CARE
1. Keep the griddle plate clean by wiping frequently with an absorbent cloth. A spatula can be
used to remove food particles.
2. Do not cook foods that produce grease as this griddle is not equipped with a gutter or
grease can.
3. Do not use a griddle stone or steel wool on the plate surface.
4. Limit preheat time to 15 to 20 minutes.
5. Avoid dropping water on the plate.
6. Keep the appliance free of grease and debris build-up.
7. Lubricate the shaft bearings every 2 to 4 weeks (depending on use) with good quality
temperature-resistant grease. When lubricating bearings, add grease slowly while shaft is
rotating. When grease begins to come out of the seals, the bearing will contain the correct
amount of lubricant. Wipe away any excess grease.
SERVICING
A qualified technician should perform servicing. Contact the factory for the local authorized
representative.
This appliance is serviceable to the front. It is suggested to provide at least 36 inches to the
front of the appliance for servicing and for proper operation.
IMPORTANT: When the appliance is equipped with casters, the installation shall be made with
a connector that complies with the Standard for Connectors for Movable Gas Appliance, ANSI
Z21.69-1987, and Addenda, Z21-69-1989, and a quick-disconnect device that complies with the
Standard for Quick-Disconnect Device for Use With Gas Fuel, ANSI Z21.41-1989. Adequate
means must be provided to limit the movement of the appliance without depending on the
WARNING: FOR YOUR SAFETY, DISCONNECT GAS AND
POWER SUPPLY TO THE APPLIANCE BEFORE SERVICE.