Jadever JWI 700C Instruction Manual

Summary of JWI 700C

  • Page 1

    Jwi-700c 0 table of contents 1. Introduction ……………………………………………………………………………… 1 2. Precaution ……………………………………………………....................................... 1 3. Product introduction 3-1 specifications & features……………………………………………………………….... 3-2 front panel 3-2-1 display …………………………………………………………………………………… 3...

  • Page 2

    Jwi-700c 1 1. Introduction thank you for deciding to purchase a jwi-700c counting indicator from jadever. This goods has the excellent performance and splendid properties under severe quality management .It is recommended to read this manual in full before using it for good function application. 2. ...

  • Page 3

    Jwi-700c 2 features ‧lcd display 6/5/6, led backlight ‧kg and lb switchable ‧up to 1/30000 resolution ‧ adjustable capacities, resolutions and parameters ‧adjustable stand for bench scale ‧enclosed with pvc dustproof cover ‧able to adjust filter range and zero band ‧low battery and charging status i...

  • Page 4: 0 ~9

    Jwi-700c 3 3) center of zero indication, the zeroing range is ±2﹪of weighing capacity. 4) charge lamp 5) hi lamp (on) –indicating parameter item is selected when setting buzz sounds. (see 5. Function setting, setting buzz sounds) ok lamp (on) -- indicating parameter item or is selected when setting ...

  • Page 5

    Jwi-700c 4 2) ● key decimal point ; toggles between upper limit and lower limit setting when hi-lo-ok function is enabled .(see 7-2-1) 3) print key outputs data when prt.Pr (print stably) is selected as the print mode. 4) zero key zeros the display (within 2% of max.Capacity) or cancels tare action....

  • Page 6

    Jwi-700c 5 3-4 power supply please verify the local ac power source and switch the two-stage switch to the proper place before plugging into the power outlet. Alternative power supply 1) ac 110v/220v (ac±10%) 2) (6v/4a) internal rechargeable battery power consumption about 300mw, 80hrs (without back...

  • Page 7

    Jwi-700c 6 step 1: thread the wire of the load cell (9)on the rod seat (1) through the upright pole (2), insert the upright pole into the rod seat and then lock it with two screws (5). Step 2: after threading the load cell wire through the bracket (3), attach the bracket to the upright pole and then...

  • Page 8

    Jwi-700c 7 5. Setting mode 5-1 maximum weighing capacity setting 1) turn on the power while pressing key zero . 2) press key ● to cycle through weight capacity options. Available settings are 15,30,60,75,150,300,600, 750,1500,3000,6000 and7500 (kg).Here we choose (75kg). 3)press key smpl to save and...

  • Page 9

    Jwi-700c 8 5-3 function setting 1) turn on the power while pressing key zero . Note: the following steps (2) ~ (11) do not require to operate in order. 2) press numeric key 0 to shift backlight modes. Options are on, off and onoff. =auto-on with items greater than 9d placed on the pan. = no backligh...

  • Page 10

    Jwi-700c 9 = there will be a warning sound when the material quantity is less than the lower limit, and the weight of the material is more than 20 divisions. = no sound alarm. 8) press numeric key 8 to set whether to save the upper & lower limit of quantity checking. . = previously set quantity chec...

  • Page 11

    Jwi-700c 10 6-1 linear calibration 1)turn on the power while pressing key tare to initiate linear calibration. 2) again press key tare to enter zero calibration mode, with “ ”flashing on the weight window. 3) wait till “ ” appears put weights of 1/3 of full load on the weighing pan and press down ke...

  • Page 12

    Jwi-700c 11 4) wait till “” ”is stable, key in the calibration value 25(1/3 full load) and put the corresponding weights on, then press key uws . “25” is flashing. 5) the calibration procedure is completed with a“ ” flashing on the weight screen. Now, remove all the weights. 6) press key smpl to sav...

  • Page 13

    Jwi-700c 12 7-1-3 unit switch operation 1) press key smpl while powering on the scale. 2) key in 1132 via numeric keys. 3) again press key smpl to enter unit selection mode. Numeric key 1 is to toggle between kg and lb units. 4) press key smpl to save, and then press key zero to return to the weighi...

  • Page 14

    Jwi-700c 13 note: symbol “ ” points at “uw” when entered unit weight is lower than 4/5 of scale division. 7-2-3 sample counting & acai sample counting 1) place samples onto the weighing pan (or into a tared container) and input the quantity with numeric keys, then press key smpl . The unit weight is...

  • Page 15

    Jwi-700c 14 3) put the second piece of load on, then press key m+ to add the second accumulation event into memory. Repeat step 2-3 till accumulation actions are finished. Note: maximum is 99 pieces. Accumulation display press key mr to displays the total accumulation data (weight, count and number ...

  • Page 16

    Jwi-700c 15 8-2 single option 1) rs232+rtc+relay+ tdp / sh-24(tp)/ zebra / godex printer 2) rs232+rtc+relay+ led light tower (applicable to the quality control of the factory product quantity or weight and that of the total production line.) 3) rs232+rtc+relay+computer 8-4 rs-232 output format baud ...

  • Page 17

    Jwi-700c 16 9. Troubleshooting and error message error message problems solutions initial zero point exceeds + /-30% (take 30% as reference basis). 1. To check whether there are other alien articles on the scale pan, remove those articles. 2. Load cell failure, which requires to be changed or to con...

  • Page 18

    Jwi-700c 17.

  • Page 19

    Jwi-700c 18.

  • Page 20

    Jwi-700c 19.