Jbc NANE-B Manual - page 6
www.jbctools.com
- Replace a blown fuse as follows:
- Replace any defective or damaged pieces. Use original JBC spare parts only.
- Repairs should only be performed by a JBC authorized technical service.
10
11
Manage and monitor the station using a Robotic system.
Working with Robots
Update the station software
1.
Download the JBC Updater software from
www.jbctools.com/software.html
and save
it on a USB flash drive. Preferably one with
no other files.
2.
Insert the USB flash drive.
The icon is diplayed while updating.
JBC
Updater
Clean
periodically
1.
Connect the tool to the port and connect your Robot system to the Robot connector (RJ12).
DB9-RJ12 Adapater available only if necessary (Ref: 0013772).
3.
Enable the Robot option in the station settings and the notification will be displayed:
4.
Set your Robot’s commands according to the Robot Communication Protocol, available on the
website
www.jbctools.com/jbcsoftware-menu-115.html
.
Control
Unit
Robot
RS-232
connection
Maintenance
1.
Pull off the fuse holder and remove the
fuse. If necessary use a tool to lever it off.
2.
Press the new fuse into the fuse holder
and replace it in the station.
- Use a damp cloth to keep the casing and
the tool clean. Alcohol can only be used to
clean the metal parts.
- Periodically check that the metal parts of
the tool and stand are clean so that the
station can detect the tool status.
Fuse holder
Fuse
holder
- Maintain tip surface clean and tinned prior
to storage in order to avoid tip oxidation.
Rusty and dirty surfaces reduce heat
transfer to the solder joint.
- Periodically check all cables and tubes.
Fuse
Before carrying out maintenance, always allow the equipment to cool.
- Clean the station screen with a glass cleaner
or a damp cloth.