JBL Northridge E-Series E150P Service Manual - Operation

Other manuals for Northridge E-Series E150P: Service Manual, Owner's Manual
Manual is about: E-Series, Performance Series

Summary of Northridge E-Series E150P

  • Page 1

    Northridge ™ e-series e150p powered subwoofer service manual jbl consumer products 250 crossways park dr. Woodbury, new york 11797 rev2 2/2004.

  • Page 2: -  Contents  -

    - contents - basic specifications …………….……..…………..1 safety information …………….……..….………..2 detailed specifications ……….……..…………..3 connections………………………...……..…...…..…4 operation ……..………………….……...…….….…...7 basic troubleshooting..………….………………8 exploded view/parts list…….….….…………....9 test set-up and pr...

  • Page 3: Safety Information

    Warning any person performing service of this unit will be exposed to hazardous voltages and the risk of electric shock. It is assumed that any person who removes the amplifier from this cabinet has been properly trained in protecting against avoidable injury and shock. Therefore, any service proced...

  • Page 4

    Jbl e150p powered sub/ plate amp line voltage yes/no hi/lo line nom. Unit notes us 120vac/60hz yes 108-132 120 vrms normal operation eu 230vac/50-60hz yes 207-264 230 vrms normal operation, moms required parameter specification unit qa test limits conditions notes amp section type (class ab, d, othe...

  • Page 5

    Parameter specification unit qa test limits conditions notes turn-off transient 50 mv-peak 2v-pp @ speaker outputs ac line cycled from on to off efficiency efficiency 65 % 64 nominal line voltage 120 vac / 230 vac stand-by input power 15 watts 18 @ nom. Line voltage auto turn of time (t) must be 5 >...

  • Page 6: +     –

    Use this installation method only with an analog receiver/ processor that does not have digital processing or bass management, and also does not have a subwoofer output or a volume-controlled preamp (line-) level output: connect the speaker wires for both your main left and right speakers, and for t...

  • Page 7

    Digital receiver/processor – lfe connection use this installation method for dolby digital, dts ® or other digital surround processors that have bass-management programming, or for analog receivers/processors that have a filtered subwoofer output: important: make sure that the lfe toggle switch on t...

  • Page 8: Operation

    Operation when the unit is plugged in and the power switch is on and no signal is received, the led on the top of the unit will turn red. When a signal is present, the led will turn green. Note: it will take several min- utes for the led to turn from green to red after the input signal to the subwoo...

  • Page 9: Troubleshooting

    Troubleshooting if you used the high-level (speaker) inputs and there is no sound from any of the speakers: • check that the receiver/ amplifier is on and a source is playing. • check that the powered subwoofer is plugged into an active electrical outlet and is switched on. • check all wires and con...

  • Page 10: E150P

    Ref# part number description qty 1 350883-001 manual, owner-e150p/e250p 1 2 350884-002 carton,master-e150p (beech model) 1 350884-001 carton,master-e150p (black model) 1 350884-003 carton,master-e150p (cherry model) 1 3 350885-001 pad,end,top-e150p 1 4 350885-002 pad,end,bot-e150p 1 5 338381-001 war...

  • Page 11: Test Set-Up and Procedure

    E150p test set-up and procedure general function uut = unit under test 1) connect one line level input cable (rca) from signal generator to either right or left level input on uut. Level control should be full counterclockwise (min). Make sure the lfe/normal switch is in the normal position. 2) turn...

  • Page 12

    E150p 11.

  • Page 13

    Tech tips troubleshooting tips and solutions to common service problems for models: e150p,e250p and pb10,pb12 (revision 2) * tip# jbltt2003-04 rev1 subject: replacing mosfets q18, q22 in the event you need to replace mosfet transistors q18 or q22 as part of a repair, it is important to use only the ...

  • Page 14

    A. Power amp section resistance check resistance from s+ (spk o/p) to gnd should be >1m Ω (no load) resistance from v+ (c6 p+) to v- (c8 p-) gradually fully charged should read >10k Ω resistance from v+ (c6 p+) to s+ (spk o/p) should read >1m Ω resistance from v- (c8 p-) to s+ (spk o/p) should read ...

  • Page 15

    - voltage measurements op amp u2(1) u2(14) u2(8) u3(7) u3(1) u3(14) u3(8) u5(7) u5(1) speaker o/p 133.6mv 200.2mv 245.9mv 314.8mv 314.9mv 350mv 1.67v 1.452v 2.098v 15.3v 2. High level input sensitivity -set up turn level, x’over freq pot fully cw and lfe switch off set generator at 1.15v@50hz signal...

  • Page 16

    Caution : speaker output is floating and is not protected against a short to ground. All test instruments connected to the output must be floating. Attach the scope probe tip to s - and reference lead to s+. (a 10mv signal may need from the input to trigger the switch turn on) no no yes yes no no ye...

  • Page 17

    E150p 16.

  • Page 18

    E150p 17.

  • Page 19

    E150p 18.

  • Page 20

    E150p 19.

  • Page 21

    E150p electrical parts list part number description reference designator qty resistors 020-000498-120 carbon film 0r 1/4w j r10,11 2 021-100401-120 mof resistor 1k 1w j r103 1 021-820303-020 mof resistor 820r 3ws j 8x20 r6,9 2 022-500003-020 knp resistor 0r05 3ws j fk type r104 1 024-100298-120 smd ...

  • Page 22

    Part number description reference designator qty 024-470798-120 smd resistor 4m7 1/8w j 0805 r60 1 024-560498-120 smd resistor 5k6 1/8w j 0805 r40,41 2 024-604598-100 smd resistor 60k4 1/8w f 0805 r39 1 024-620398-120 smd resistor 620r 1/8w j 0805 r16,18,57 3 024-680498-120 smd resistor 6k8 1/8w j 0...

  • Page 23

    Part number description reference designator qty 051-222200-100 npn transistor pn:mps2222arlra to-92 q21 1 051-290700-100 pnp transistor pn:mps2907a rlra to-92 q19,23 2 051-540101-000 pnp transistor pn:2n5401 to-92 q1 1 051-555100-000 npn transistor pn:2n5551 to-92 q17 1 051-640001-000 mosfet n-chan...

  • Page 24

    Part number description reference designator qty 072-040096-000 terminal (t=0.8mm) pc187(0.8) 072-040169-000 connector 2 pin js-1001-2 p:2.5mm 072-060170-000 b.P. W / accessory parts 073-032316-601 black anodized 70x42x20mm 073-050001-000 fuse clip p/n:cffh1206 074-020018-000 rocker sw pn:rf1003-bb4...

  • Page 25

    Opamp, quad tl074cdr u2, 3 opamp, dual tl072cdr so-8, njm4558m-te3 u5, 6, 4 ir2111 half-bridge driver u7 2 base 3 collector 1 emitter 1 2 3 2n5401 q1 2 base 3 collector 1 emitter 1 2 3 mpsw06rlra, mpsw56rlrampq, mps2222arlra, 2n2907a, 2n5551, q2, 16, 3, 21, 19, 23, 17 mosfet irf640 q18, 22 tip31c q4...

  • Page 26

    音 律 電 子 股 份 有 限 公 司 音 律 電 子 股 份 有 限 公 司 e150p 25 note: this voltage is referenced to -v, not circuit ground note: this voltage is referenced to -v, not circuit ground.

  • Page 27

    音 律 電 子 股 份 有 限 公 司 音 律 電 子 股 份 有 限 公 司 e150p 26 note: this voltage is referenced to -v, not circuit ground.

  • Page 28: E150P

    1 5 3 14 2 4 e150p packaging ref# part number description qty 1 350883-001 manual, owner-e150p/e250p 1 2 350884-002 carton,master-e150p (beech model) 1 350884-001 carton,master-e150p (black model) 1 350884-003 carton,master-e150p (cherry model) 1 3 350885-001 pad,end,top-e150p 1 4 350885-002 pad,end...