JEM Glaciator X-Stream User Manual - page 2
Fluids Suitable for this system:
Heavy Fog
Fluid B2
Heavy Fog
Fluid C3
HEAVY FOG GLACIATOR
NOTE! The warranty on this machine is conditional on the use of
genuine JEM / Martin fluid only. Other fluids may represent a health
hazard when used in this machine, and may damage the internal
components.
CONNECTIONS
HEAVY FOG GLACIATOR
21
REMOTE
INTERF
ACE
1-GND, 2-12V OUT, 3-INPUT
1 FOG
2 STANDBY
3 TIMER
4 FAN
5 LOW FLUID
6 GND
7
8 REMOTE PUMP
9 REMOTE PUMP
DMX
ADDRESS
1
2
4
8
16
32
64
128
256
SPECIAL 1
SPECIAL 2
SPECIAL 3
ON
1
2
3
4
5
6
7
8
9
10
11
12
DMX
D
A
TA
INPUT
IN
OUT
1
5
6
9
1 GND
2 COLD
3 HOT
FUSE RATINGS
The Heavy Fog Glaciator uses
six fuses.
They should be replaced with
the value and type detailed
below:
DMX receiver low voltage
2AT
Power PCB
15AT
Compressor control relay
3.15AT
Local/Remote relay
3.15AT
Condenser fan relay
3.15AT
External pump signal
1AT
These fuses are located
internally and should not be
accessed without first
disconnecting the power supply.
FILTERS
The Heavy Fog Glaciator uses
a washable synthetic fibre filter
in the air intake for the
condenser unit (located at the
top of the machine). This can
be removed for cleaning by
removing the ventilation grill
above it (four M5 screws). Use
the following guidelines for
when to check the filter.
:
Inspect and clean/replace every
250 hours
:
Inspect and clean/replace every
150 hours
Normal Conditions
Severe Conditions