JEM Glaciator X-Stream User Manual - page 3
SPECIFICATION
HEAT EXCHANGER
FLUID SYSTEM
CONTROL PANEL
REFRIGERATION UNIT
OUTPUT CONNECTION
3.5KW heater (@240V)
Wide bore steel vaporizing coil
Ceramic thermal trip for over-temperature protection
Electronic Temperature control using thermocouple
Oscillating piston high pressure fluid pump
Low fluid detection by electronic sensor
5L fluid container (1.3 US Gal.)
DMX512 decoder:
Required Channels = 2
Output is proportional for all levels above 12%
Channels supported = 1 to 511
Valid start codes = 0 (dimmer data only)
Full framing error detection implemented
Analogue control via standard JEM Multifunction Contoller.
PLC interface for simple switching control of the system.
2 x LED displays with 4 button keypad
Output level control from 0 to 100% for Fog
Timer range:
Delay time (toF) 0 seconds - 90 seconds
Run time (ton) 0 seconds - 90 seconds
1 HP compressor with PWM electronic control
Uses refrigerant R404A (1.2 Kg)
Ducting adaptor to accept 150mm (6”) flexible ducting
Maximum fluid consumption 120mL/minute
REMOTE CONTROL OPTIONS
POWER REQUIREMENTS (dependant on model)
Input voltage
single phase (32A supply)
Input power (max) 4.893KW @ 230V
Current (max) 22.2A
Input voltage
single phase (32A supply)
Input power (max) 4.325KW @ 208V
Current (max) 21.9A
Power connection is via 32A 3 pin IEC appliance inlet (230V machines)
or fixed cable (208V machines).
230V,50Hz
208V,60Hz
HEAVY FOG GLACIATOR
USER
GUIDE
20
HEAVY FOG GLACIATOR
USER
GUIDE
USER GUIDE CONTENTS
Introduction
2
Features
2
Safety Guidelines
3
Machine Layout
4
Commissioning The Machine
5
Remote Control Options
5
DMX Operation
6
The Display
8
Local Remote Fluid System
11
Refrigeration System Control
12
Evaporator Fan Control
13
Condenser Temperature Control
13
Control Panel Functions
14
The Timer
15
Basic Operation
16
Interface Options For Glaciator X-stream
17
Display Messages
18
Basic Fault Finding
19
Specification
20
Connections
21
Fuse Ratings
21
Filter Maintenance
21
The Fluid System
10
1
©
Martin Professional A/S, Denmark.
2003
All rights reserved. No part of this manual may be reproduced, in any form or
by any means, without permission in writing from Martin Professional A/S,
Denmark.