    Operations manual e-plex ® 2000 series e-plex ® powerstar 2000 series.

  • Page 2: Table Of Contents

    2 table of contents introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4 e2000 operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4 eps2000 operation . . . . . ....

  • Page 3: July 2010

    3 july 2010 r. Activate / de-activate passage mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .20 s. De-activate user access codes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .20 t. De-activate manager access codes . . . . . . . . . . . . . . . . . . . . ...

  • Page 4: Introduction

    4 introduction the e-plex 2000 (e2000) and the e-plex powerstar 2000 (eps2000) are both easy to use pin only lock series that do not require any software to operate. E2000 operation the e2000 uses three (3) aa alkaline batteries. This means that anytime you can simply access the lock with your valid...

  • Page 5

    5 important: when you pump the handle, the lock will flash the green light once accompanied by a high pitched beep indicating that it is “ready”—either for you to enter your valid access pin, or for you to start programming. If you do not pump the handle, there will be no response from the lock and ...

  • Page 6: States Of The Lock

    6 states of the lock factory mode the factory mode is one of three primary states of the e-plex 2000 and the e-plex powerstar 2000. The main characteristics of this state are: • the e2000/eps2000 opens only when the 8-digit master combination (1-2- 3-4-5-6-7-8) is keyed in. • the visual indication f...

  • Page 7: Programmable Parameters

    7 default values of the e-plex 2000 programmable parameters parameters factory default values lock state unprogrammed passage mode open time limit 9 hours passage mode de-activated lockout mode de-activated unlock time 2 seconds buzzer volume control low tamper shutdown time 30 seconds tamper attemp...

  • Page 8

    8 for example • if the master or manager enters his code of 87654321, the door will open. • if he enters #87654321#, the lock will enter into the programming mode and wait for the next part of the command. • if he enters the # sign twice at the end of the code, for example #87654321##, the lock will...

  • Page 9

    9 a. Program the access code length setting the length of access codes must be the first lock programmable func- tion you perform, because all your other access codes must have the same length. If a user enters a code of a different length, the lock will not accept it. Longer length access codes per...

  • Page 10: The Passage Mode Period

    10 c. Program the unlock time unlock time is the length of time the door will remain unlocked when a correct code is entered before automatically re-locking itself. Required user level: master, manager c-1 put the lock into pushbutton programming mode. C-2 to establish unlock time, enter the followi...

  • Page 11: E. Program The Lock For

    11 e. Program the lock for tamper time parameters you can set a tamper time wrong tries parameter referring to the number of times the wrong code can be entered before the lock goes into tamper shutdown mode. For example, if you program the lock to accept three wrong tries, the lock will tolerate th...

  • Page 12

    12 f-3 example of complete entry: 008#02#. F-4 enter another # to indicate the end of programming. F-5 the lock will now sound the buzzer at the desired volume normal, until you change it. Users - general information 1. Master and manager codes can do two different things: • open the door by enterin...

  • Page 13: User Codes

    13 service user - a user with an access code valid for a configurable period of time. This period of time starts on the first use of the code. Each service user combina- tion is automatically deleted after its period of time expires. The number of service users is limited only by available user tabl...

  • Page 14

    14 kaba access control warrants the e-plex 2000 to be free from defects in material and workmanship under normal use and service for a period of two (2) years from initial instal- lation date. Kaba access control will repair or replace, at our discre- tion, e-plex 2000 locks found by kaba access con...

  • Page 15

    K a b a a c c e s s c o n t r o l 2 9 4 1 in d ia n a a v e n u e w in s t o n -s a l e m , n c 2 7 19 9 -3 7 7 0 n o p o s t a g e n e c e s s a r y if m a il e d in t h e u n it e d s t a t e s b u s i n e s s r e p l y m a il f ir s t -c l a s s m a il p e r m it n o . 15 6 3 p o s t a g e w il l...

  • Page 16

    T h a n k y o u f o r p u r c h a s in g o u r p r o d u c t. I n o r d e r t o p r o te c t y o u r i n v e s tm e n t a n d t o e n a b le u s t o b e t- te r s e r v e y o u in t h e f u tu re , p le a s e f ill o u t th is r e g is - tr a ti o n c a r d a n d r e tu r n i t to k a b a a c c e s ...

  • Page 17

    15 g. Add/modify a user access code • when users no longer need access to the lock, delete the user code. This permits you to use the number for a new user. • if you only de-activate the old code, you cannot add a user with the same number. De-activate should only be used when the user is, for examp...

  • Page 18

    16 h-5 enter the code 1224# again. H-6 example of complete entry: 101#024#1224#1224#. H-7 enter another # to indicate the end of programming. H-8 the manager access code 1224 will now work in that door with all the access privileges assigned to a manager user. H-9 manager users can open the door by ...

  • Page 19

    17 j. Delete user access codes user access codes should be deleted if no longer needed. This frees the num- bers to be assigned to another user. Codes that may be needed some time in the future should be de-activated rather than deleted. Required user level: master, manager j-1 put the lock into pus...

  • Page 20: Except Master And Manager

    18 l-4 example of complete entry: 202#025#. L-5 enter another # to indicate the end of programming. L-6 you have now deleted a service user id location, and (indirectly) his access code, allowing you to assign that number to another service user if you wish. M. Delete all access codes except master ...

  • Page 21

    19 o. Activate manager access code a manager code should be activated if it has been de-activated for a certain time period - during a manager’s vacation, for example, or if you created a manager’s code, but never assigned it to anyone. Required user level: master o-1 put the lock into pushbutton pr...

  • Page 22

    20 r. Activate/de-activate passage mode you have already programmed a default duration for a door to remain in passage mode. When you enable passage mode, it becomes enabled for the duration you have set in procedure 5 - program the duration of the passage mode period, on page 9. The duration featur...

  • Page 23: Except Master And Manager

    21 required user level: master t-1 put the lock into pushbutton programming mode. T-2 enter command 401# to de-activate a manager access code. T3 enter the code 401#nnn#, where nnn is the specific manager id location, 024 for example. T-4 example of complete entry: 401#024#. T-5 enter another # to i...

  • Page 24

    22 w. Activate/de-activate lockout mode you may need to use lockout mode, for example, during a fire or fire drill when you do not want anyone to return to his or her office. This procedure will de- activate all regular user access codes that are active, including manager codes, but excluding the ma...

  • Page 25

    23 battery life and replacement a variety of factors (shelf life, openings per day, environment, battery brand, lock settings, etc.) will determine how long your lock operates on a set of bat- teries. In average conditions, you can expect a minimum of 100,000 openings for e-plex 2000 models with 3 “...

  • Page 26

    24 summary of pushbutton programming commands name add/modify users delete users command 100 # nnn # uuuu {uuuu}# uuuu {uuuu}# 101 # nnn # uuuu {uuuu}# uuuu {uuuu}# 102 # nnn # uuuu {uuuu}# uuuu {uuuu}# hh# 200 # nnn# 201 # nnn# 202 # nnn# 299 # description of command ‘add/modify user access code’ n...

  • Page 27

    25 summary of pushbutton programming commands name activate users de-activate users diagnostic command 300 # nnn# 301 # nnn# 302 # nnn# 398 # 399 # p# 400 # nnn# 401 # nnn# 402 # nnn# 498 # 499 # l# 500 # 123456789*0# description of command ‘activate user access code’ nnn = specific user id location...

  • Page 28

    26 visual feedback message definitions condition parameters green led red led duration rate valid pushbutton on off 1/10 sec once pressed timeout expired off on 1 sec; a once valid access on off 1 sec once code keyed access granted on off 1/10 sec 1 sec access granted on on 1/10 sec 1 sec (battery l...

  • Page 29

    27 e-plex 2000 user list table user # access code user name user type 001 002 003 004 005 006 007 008 009 010 011 012 013 014 015 016 017 099.

  • Page 30

    28 notes.