Kaco Powador-proLOG Operating Instructions Manual - Important
Page 38
38
Operating Instructions Powador-proLOG_EN
Section 8 ·
Menu Description
Static IP address
Indicates the desired IP address when no boot protocol is
used.
Netmask
The subnet mask that is used when one was not assigned by
the BOOTP/DHCP server.
Gateway
The gateway that is used when one was not assigned by the
BOOTP/DHCP server.
–
Primary DNS server
You can enter the DNS server in this field.
–
Secondary DNS server
You can enter an alternate DNS server in this field.
The ISDN terminal adapter settings pertain to the Powador-
proLOG’s ISDN settings. To use the unit on an ISDN extension,
enter the relevant connection number here.
MSN
Connection number for the ISDN extension, which is usually
a phone number without prefix.
The settings for testing the reporting methods are used to test
the Powador-proLOG’s ability to make contact. The test can be
conducted by e-mail, fax and SMS (text message).
Test contact
The contact for sending a test message. You can use the
standard contact or specify one of the four contact addresses.
Place a check next to the relevant fields to activate the desired
form of contact (E-mail, Fax, or Text message).
2. Internet
This section contains settings for the Internet access points
(provider settings), which the Powador-proLOG uses to con-
nect to the Internet. Enter the designation, access number,
user name and password.
3. E-mail
This section is where you make settings that pertain to the
sending of e-mail messages.
The SMTP server (outbox) section includes settings for IP
address and e-mail address. This information is needed for the
Powador-proLOG to send e-mail messages.
–
SMTP Server IP Address
The IP address for logging on to the e-mail server. The
IP address of our data processing centre is
213.179.128.176.
You can set the priority of the providers in the ”Admin Moni-
toring » Network » Internet” section. This means that the first
provider listed will be dialled first. If no connection is made,
the Powador-proLOG dials up the next provider.
–
Datalogger Email Address
Enter a valid e-mail address here.
The e-mail address must include the relevant SMTP
server. Standard e-mail address: sr@direct-data.de
–
Group Email Address
KACO new energy provides a service for sending e-mail
messages using a server in our data processing centre.
To use it, enter the address data@mail1.meteocontrol.
de. The e-mail messages will then be forwarded to the
actual address.
The POP3 server “inbox” section includes settings for authen-
tication, IP address, user name and password. Fill in these
fields only if they are required by the e-mail account. The
server in our data processing centre does not require them.
IMPORTANT
Your changes are not applied until you press the “Save”
button.
IMPORTANT
Your changes are not applied until you press the “Save”
button.
IMPORTANT
Sending e-mail messages via the Ethernet interface: If
you want to send e-mail messages through the local net-
work (e.g. via DSL), make sure that no provider is selected.