Kaltis ULTRA LOW TEMPERATURE FREEZER User Manual - 4. Pre-Installation
4. Pre-Installation
On delivery, unpack the unit and check the cabinet exterior for signs of damage.
CAUTION!
Do not discard the internal lids from chest-style units. These lids are
necessary to maintain the correct temperature, moisture control, and general
operational efficiency.
5. Installation
Do not deviate from the electric and temperature ratings printed on the data plate
located on the rear, lower right side of the unit.
CAUTION!
Incorrect operation of the equipment could result in potentially dangerous
conditions. To avoid hazards and minimize risk, follow all instructions and
operate the unit within the limits stated on the data plate.
5.1 Positioning
Install the unit on a vibration free, level floor, with a minimum of fifteen centimeters
of space on the sides, rear, and top. Refer to Section 5.3 for instructions on leveling
cabinets. Allow enough clearance so that door or lid can open at least 90 degrees.
Do not position the equipment in direct sunlight or near sources of heat such as
diffusers, radiators etc. The ambient temperature range at the site must be 15°C to
32
o
C.
WARNING!
Install the unit on a sturdy floor.
WARNING!
Never install the unit in a flammable or volatile location. This may
result in fire or explosion.
Never install the unit where acid or corrosive gases are present.
Current leakage or electric shock may result due to corrosion.
9