Kalvis K-2-16 User's Installation And Operation Manual

Summary of K-2-16

  • Page 1

    ® central heating boiler on solid fuel kalvis-2-16, 2-25, 2-30, 2-40 users installation and operation manual certificate no. Spsc-5199.

  • Page 2

    - 2 -.

  • Page 3

    - 3 - attention ! Get acquainted with this technical certificate before installing the boiler. 1. Technical data. Central heating boiler "kalvis-2-16, 2-25, 2-30, 2-40" (hereinafteer referred to as the boiler) is used for heating of various premises where central heating system with natural or force...

  • Page 4

    - 4 - main technical data: boiler type k-2-16 k-2-25 k-2-30 k-2-40 fuel used wood, waste wood, peat and saw dust briquettes, coal heated area 80 – 160 150 - 250 200 - 300 250 - 400 fuel load, dm 3 (l) 100 120 175 220 fire wood length up to , mm 400 350 350 450 combustion duration*: - fire wood, h. -...

  • Page 5

    - 20 - - 5 - kalvis-2-16, 2-25, 2-30, 2-40 en 2009.05.18 shoelds. Front side of the boiler has draught adjuster (p.7), which controls air supply damper (p.1), thermometer (p.6), doors (p.2), behind which there are servoce doors (p.3). Loading chamber is closed with doors (p.5). In the boielr there i...

  • Page 6

    - 6 - - 19 - kalvis-2-16, 2-25, 2-30, 2-40 en 2009.05.18 * if boiler is connected to the chimney by metal pipes, pipes should be not thinner than 1,5mm and they have to be covered by thermal insulation attention ! When chimney’s draught is too great and sawdust is used for fuel sparks may fly out th...

  • Page 7

    - 18 - 9. Complement 1. Boiler "kalvis-2-_____” 1 vnt. 2. Draught adjusterc20/25 1 vnt. 3. Grinder 1 vnt. 4. Ash scoop 1 vnt. 5. Poker 1 vnt. 6. Manual 1 vnt. 10. Product guarantee manufacturer guarantees, that the product meets technical documentation requirements. Guarantee time - 24 months from t...

  • Page 8

    - 8 - performed by a well qualified plumbing welder who is well acquainted with this manual and boiler design - 17 - kalvis-2-16, 2-25, 2-30, 2-40 en 2009.05.18 - oak wood - 500 kg; - birch wood - 450 kg; - fir wood - 330 kg; - asp wood - 330 kg. The higher wood humidity – the less calorie value. De...

  • Page 9

    - 16 - - 9 - kalvis-2-16, 2-25, 2-30, 2-40 en 2009.05.18 burner should be cleaned before every start up. Clean flame sensor when needed. Use special chemicals for hardened solids cleaning. Use swedish „fasch 300“ or cleaners used for fireplaces glass cleaning. 5.5.Consumables fire grate and cast iro...

  • Page 10

    - 10 - - 15 - kalvis-2-16, 2-25, 2-30, 2-40 en 2009.05.18 - open damper (p.1) with draught adjuster. Check the smoek color out of chimney. Smoke should be thin of a light grey color. If smoke is thick and black it means incomplete combustion, not enough secondary air. Open secondary air supply dampe...

  • Page 11

    - 14 - - 11 - kalvis-2-16, 2-25, 2-30, 2-40 en 2009.05.18 • nly persons with necessary qualification are allowed to perform installation works; • installation works should be performed according to the prepared project; 5. Boiler servicing adults that are well acquainted with the design and users ma...

  • Page 12

    - 12 - - 13 - kalvis-2-16, 2-25, 2-30, 2-40 en 2009.05.18 • boiler should be connected by hot and return water pipes not smaller than 1.5’’ in diameter • boiler may be connected to the heating system with the expansion tank, where operating pressure does not exceed 0,15 mpa (1,5 kgf/cm2); • if syste...