Kalvis K-2-16 User's Installation And Operation Manual - page 7
- 18 -
9.
Complement
1. Boiler "Kalvis-2-_____”
1 vnt.
2. Draught adjusterC20/25
1 vnt.
3. Grinder
1 vnt.
4. Ash scoop
1 vnt.
5. Poker
1 vnt.
6. Manual
1 vnt.
10.
Product guarantee
Manufacturer guarantees, that the product meets technical
documentation requirements.
Guarantee time - 24 months from the sale date.
Manufacturer will repair any malfunctions in the product that
appear due to manufacturers fault.
Manufacturer will not acknowledge any quality claims for
products operation and consequences if the product has been wrongly
chosen, mounted, installed or serviced.
Boiler complement has 12 months guarantee and consumables – 6
months.
In case of malfunction, fill in the form and send it to the
manufacturer or authorized guarantee servicing company by a
reistered mail. In emergency cases make a telephone call and give the
form to the company representatives.
I am acquanited with rules of installation and servicing and
guarantee policy.
Purchaser:
(name, last name, signature)
- 7 -
KALVIS-2-16, 2-25, 2-30, 2-40 en 2009.05.18
Bouiler connection to chimney by elbows.
* not less than 60
°
A - correct B – incorrect
Chimney insert mounting
•
If chimney is connected with additional elbow, it‘s cross section
has to be not less than that of the boiler smoke pipe, and bending
radii not less than 100mm;
•
Pipe from the smoke pipe to chimney has to be not longer than 1,5
m and lean upwards toward chimney;
•
Joints have to be well sealed;
•
Chimney hole has to be well cleaned.
Necessary to know that:
•
Smoke continues to cool in the chimney, vapor condenses on the
chimney walls, especially in the unheated loft and on the outside
of the building;
•
Condensate acids and erosion may destroy the chimney in few
years;
•
Not cleaned soot in the chimney may self-combust and become
the cause of fire.
Recommended:
•
Mount an insert into the chimney. Well mounted insert protects
chimney from condensate influence;
•
Insert should not significantly decrease the cross section of the
chimney;
•
Insert parts should be well joined together (no soldering);
•
Condensate collector and drainage should be arranged in the
bottom;
•
An incombustible material should insulate the cavity between the
insert and chimney. Top slit should be hermetically sealed;
•
In the unheated loft an incombustible material should insulate
chimney.
4.3. Requirements for the connection to the heating system:
Recommended connection schema is shown in the 4 fig.
•
Boiler may be connected to the heating system according to the
project prepared by heating equipment specialists or works may be