Kane KANE504 Owner's Manual & Maintenance Manual

Manual is about: Combustion Analyser

Summary of KANE504

  • Page 1

    Kane504 combustion analyser stock no: 19101-2 april 2012 © kane international ltd.

  • Page 2: Contents

    - 2 - contents page no: owners manual & maintenance 3 1. Getting started 4 1.1 safety notes 4 1.2 pre-test checklist 4 1.3 storing inlet temperature 4 1.4 selecting fuel 5 1.5 analyser connections 5 1.6 post test 6 2. Maintenance 6 2.1 general maintenance 6 2.2 periodic service 6 2.3 annual re-calib...

  • Page 3: Owners Manual & Maintenance

    - 3 - owners manual & maintenance the kane504 flue gas analyser tests heating appliances for carbon dioxide (co 2 ), carbon monoxide (co), flue temperature and combustion efficiency. It is suitable for use with all common ‘domestic’ fuels including natural gas, propane, heavy oil, lpg and light oil....

  • Page 4: 1. Getting

    - 4 - 1. Getting started 1.1 safety notes before using this meter, read all safety information carefully. In this manual the word “warning” is used to indicate conditions or actions that may pose physical hazards to the user. The word “caution” is used to indicate conditions or actions that may dama...

  • Page 5: 1.4 Selecting

    - 5 - ducted systems. If the kane504 is being used on a system that brings in outside air for combustion air it is important to set up the inlet temperature prior to taking flue gas readings. To properly set inlet perform the following steps during start-up of the kane504: connect the flue temperatu...

  • Page 6: 1.6 Post

    - 6 - 1.6 post test remove the probe from the flue and allow the analyser to purge with fresh air until the co and the co2 readings return to zero. (be careful as the probe tip will be hot) drain water trap. Check particle filter. 2. Maintenance 2.1 general maintenance check calibration of your inst...

  • Page 7: 2.4 Cleaning

    - 7 - 2.4 cleaning periodically clean your instrument case using a damp cloth. Do not use abrasive, flammable liquids, cleaning solvents, or strong detergents as they may damage the finish, impair safety, or affect the reliability of the structural components. 2.5 emptying and cleaning the in-line w...

  • Page 8: 2.7 Batteries

    - 8 - 2.7 batteries replacement this meter has been designed for use with alkaline batteries. No other types are recommended. The analyser is supplied with 4 “aa” size alkaline batteries. These should be installed into the instrument as shown in the diagram to the right and indicated on the back of ...

  • Page 9: 3. Meter

    - 9 - 3. Meter problem solving if any problems are not solved with these solutions, contact us or an authorised repair centre. Fault symptom causes / solutions co 2 too low air leaking into probe, tubing, water trap or connectors. Meter does not respond to flue gas particle filter blocked. Probe or ...

  • Page 10: 4. Meter

    - 10 - 4. Meter specification (note may be subject to change) parameter resolution accuracy range flue temperature carbon dioxide *1 oxygen *2 carbon monoxide *1 efficiency *3 0.1 °c 0.1% 0.1% 1 ppm 0.1% ± 2°c + 0.3% reading +0.2% +0.2% +/- 5ppm +/-5% of reading >100 ppm n/a 0-600°c 0 - 21% 0 - 21% ...

  • Page 11: 5. Electromagnetic

    - 11 - 5. Electromagnetic compatibility european council directive 89/336/eec requires electronic equipment not to generate electromagnetic disturbances exceeding defined levels and have adequate immunity levels for normal operation. Specific standards applicable to this meter are stated below. As t...

  • Page 12: 6. Glossary

    - 12 - 6. Glossary 6.1 selector and display parameters on kane504: “2er0” analyser is performing the initial zero setting. Co2 (carbon dioxide) direct reading of the carbon dioxide sensor displayed in percentage (%). Co carbon monoxide reading in parts per million. Eff (efficiency) calculated combus...

  • Page 13: 6.2 Fuels

    - 13 - 6.2 fuels available selector position display type l oil loil light oil propane prop propane nat gas ngas natural gas h oil hoil heavy oil wood wood wood coal coal coal 7. Cleaning this product can be cleaned using a damp lint free cloth and a small amount of non-abrasive detergent. Take care...

  • Page 14: Packing Your Analyser

    - 14 - 8.1 returning your analyser to kane when returning your kane504, please always ensure that you enclose: 9 your full contact details 9 a daytime telephone number 9 details of faults you might have experienced 9 any relevant accessories (eg. Probe, printer, adaptor and leak detectors). Any acce...

  • Page 15: Service Returns

    - 15 - service returns (simply cut out and attach to your package) northern service department kane international ltd gibfield park avenue atherton manchester m46 0sy northern service department kane international ltd gibfield park avenue atherton manchester m46 0sy northern service department kane ...

  • Page 16

    - 16 -.

  • Page 17

    - 17 - product registration please complete, detach and return to: kane international ltd, kane house, swallowfield, welwyn garden city, hertfordshire, al7 1jg your details name: job title: company name: company address 1: address 2: town/city: county: postcode: country: phone number: fax number: mo...

  • Page 18

    - 18 - why did you buy a kane product? Dealer recommendation made in the uk value for money our fixed price servicing programme kane previous owner not your decision other reason: what brand was your previous analyser? 1 st time purchase kane testo telegan anton tpi other manufacturer: how did you h...

  • Page 19

    - 19 -.