Kantech ioProx P600 Installation Manual - 1.1 Specifications
P600 ioProx Long Range Proximity Reader
Installation Manual
DN5084-0804
7
Chapter 1 • System Overview
The P600 Long Range Reader is a self-contained and weather sealed proximity reader designed
for outdoor and indoor use. The two-piece polycarbonate cover fits tightly over a foam gasket,
offering security against weather.
A cable fitting (strain relief) seals the cable entry. The reader uses a non-shielded 18AWG to 22
AWG cable. The P600 Long Range Proximity Reader can be powered from 12VDC to 28VDC.
A bi-color LED and audible tone provide user feedback.
A single dipswitch gives field configuration for Kantech Extended Secure Format (XSF) or 26-bit
Wiegand data output format.
A tamper switch alerts the host (controller) of intrusion. Closing the cover activates the tamper
switch by pressing down the post on the lever of the switch.
1.1 Specifications
Typical read range..............................Up to 29" (73 cm)
Input voltage ......................................12 to 28 VDC
Maximum peak current ......................1A
Dimensions (H x W x D) in ..............11.25 x 11.25 x 1.25
Dimensions (H x W x D) cm .............28.5 x 28.5 x 3.15
Color ..................................................Black
Transmit frequency ............................125 KHz
LED indicator ....................................Bicolor (red and green)
Piezo buzzer .......................................Integrated
Tamper switch ....................................Integrated (normally closed when secured)
Operating temperatures......................-35ºC to 65ºC (-30ºF to 150ºF)
Reader format ....................................26-bit Wiegand or Kantech XSF format (field selectable)
Cable ..................................................18 AWG or 22 AWG wires (For details, refer to Table
“Cable Length and Reading Range” on page 11)
Compatible cards ...............................P10SHL, P20DYE, P30DMG, P40KEY.
Certification .......................................FCC Part 15, Class B; ICES-003; UL294;
CE approved (EN 55022, EN 50130-4, EN 60950)
Note
For best reading results it is strongly recommended to use 18 AWG non-shielded cable
such as BELDEN 5304UE (six wires) or BELDEN 5306UE (eight wires) when the tamper
switch is used. Best reading results are obtained when a 12 VDC power supply is used.