Kantech ioProx P600 Installation Manual - 2.1 Opening The Enclosure
P600 ioProx Long Range Proximity Reader
Installation Manual
DN5084-0804
9
Chapter 2 • Installing the P600 Proximity Long Range Reader
In choosing a location for mounting the reader, keep the following considerations in mind: no
metallic and PC monitor should be near the P600 location (10 m (30 feet) minimum).
The reader can be installed on:
•
A wall,
•
A single or double gang electrical box,
•
An electrical post,
•
A goose neck or pedestal.
The P600 can be mounted and installed in seven easy steps:
1. Opening the enclosure,
2. Setting the required data format (Kantech XSF or 26-bit Wiegand),
3. Installing the strain relief and connecting the cable,
4. Mounting the reader to its location,
5. Closing the enclosure,
6. Powering up the power supply and the host (12 or 24VDC),
7. Verifying the reading with a transponder (card).
2.1 Opening the Enclosure
It is easy to open and close the enclosure. Three sets of attachments allow you to open and close
the casing as illustrated by Figure 1.
•
Two hinges on the top of the unit that give an angular movement of 15º from the base,
•
A notch on the bottom of the case that temporarily holds the cover over the base,
•
Two screws that insure the robustness and seal of the enclosure.