Keating Of Chicago SERIES 2006 User Manual - Troubleshooting Chart
12
Problem
Probable Cause
Solution
Main power light does not come on. a.Fryer not plugged in.
b.Breaker has tripped.
c. Main power switch is faulty.
a.Plug fryer into approved outlet. Must
be properly grounded.
b.Reset the breaker lcoated on the
bottom of the control panel
c. Replace the main power switch.
Blower light does not come on.
a.Thermostat not turned on.
b.If blower comes on, blower light is
faulty.
c. If Over Maximum Temperature light is
on, Hi-Limit has been activated.
d.If unit has a filter, drain handle not
locked into place.
a.Set thermostat to desired
temperature.
b.Replace blower light.
c. Reset Hi-Limit after oil has cooled
down below 425°F. Correct problem
which caused Hi-Limit to activate
(See page 10).
d.Secure drain handle in place
behind the bracket.
Burner light does not come on.
• Check for flame at each burner. If
no flame is present at either burner:
a.Spark module is faulty.
• Check for flame at each burner. If
flame is present at both burners:
b.Burner light is faulty.
a.Replace spark module.
b.Replace burner light.
Burner light comes on, then goes
out (after 2 1/2 seconds).
• Check for spark at each burner. If
no spark at either burner:
a.Spark electrode wires are not tight or
faulty.
b.Spark electrode is faulty or is out
of alignment.
• Check for spark at each burner. If
spark occurs at both burners:
c. Gas is not hooked up properly or
not turned on.
d.Spark electrode is faulty or is out
of alignment.
e.Combination gas valve is faulty.
a.Tighten spark electrode wires or
replace.
b.See detail on page 26.
c. Turn manual gas valve on. If using
flexible connector with quick
disconnect, make sure that the quick
disconnect is completely engaged.
d.Align spark electrode. Replace spark
electrode if faulty. Gap must be 1/8"
between electrode and pilot tube and
between pilot tube and burner (See
page 26).
e.Replace combination gas valve after
verifying it has voltage.
TROUBLESHOOTING CHART
The following diagnosis is only to be used as a guide to qualified service personnel. Keating recommends that you
use a qualified service company. Call 1-800-KEATING if you need assistance in locating a qualified service
company.
NOTE: To correctly and quickly diagnose the system, the chart below must be followed in sequential order.