Kempi KMS 400 AS Operating Manual - Installation
EN
installatiOn
3.
BeFOre use
3.1
The product is packed in specially designed transport cartons. However, before use always
make sure the products have not been damaged during transportation.
Check also that you have received the components you ordered and the instruction manuals
needed, as described in the Quick start guide pack. Product packaging material is recyclable.
NOTE!
When moving the welding machine, always lift it from the handle, never pull it from the
welding gun or other cables.
Operating environment
This machine is suitable for both indoor and outdoor use. Always make sure that the air flow to
the machine is unrestricted. The recommended operating temperature range is -20…+40°C.
Please ensure you read the safety instructions concerning operating environments supplied in
this manual.
distribution network
All regular electrical devices without special circuits generates harmonic currents into the
distribution network. High rates of harmonic current may cause losses and disturbance to
some equipments.
This equipment complies with IEC 61000-3-12 provided that the short-circuit power Ssc
is greater than or equal to 4.7 MVA at the interface point between the user’s supply and
the public supply network. It is the responsibility of the installer or user of the equipment
to ensure, by consultation with the distribution network operator if necessary, that the
equipment is connected only to a supply with a short-circuit power Ssc greater than or equal
to 4.7 MVA.
MaChine intrOduCtiOn
3.2
H12
H11
S11
X11
X12
X14
6,3A
X13
X15
01
F11
F11
Fuse for connection for control table
6.3 A delayed
X12
Earth connection
H11
Signal lamp
I/O
X14 , X15
Connection for control cable parallel
H12
Warning lamp for thermal protection
01
Inlet of mains cable
S11
Main switch
I/O
X11, X13
Welding connection
parallel
6
FastM
ig KMS 400 AS / © Kemppi O
y / 1021