Kemppi FastMig X 450 Operating Manual - page 21
EN
Control *
USER, PANEL,
REMOTE, GUN.
Factory settings is USER
This setting affects the XF 37 control
panel remote control unit selection.
USER: User can select the remote control
device at XF 37 panel
PANEL: Selection is locked to PANEL, and
user can not select the remote device at
XF 37 panel.
REMOTE: Selection is locked to HAND
REMOTE device.
GUN: Selection is locked to GUN REMOTE
device.
RemoteAutoRecog ON, OFF.
Factory setting is ON
Automatic remote control unit
recognition.
ON: Remote control units are
recognized. Wire feeder panel XF 37
jumps to PANEL selection, if the selected
remote control unit disappears.
OFF: Remote control units are not
recognized. Remote control unit
selection remains unchanged if the
selected remote control unit disappears.
MIG CurrentDisp
ON, OFF
Factory setting is OFF
ON: Displays amperage (A) preset values
OFF: Displays wire feed speed (m/min).
WFMotorWarnLev 1.5…5.0 A
Factory setting is 3.5A
The alarm level of wire feed motor
current.Check/service wire feed
mechanism, adjustment and gun
components.
WF End Step
ON, OFF
Factory setting is OFF
ON: The filler wire steps forward at the
end of the welding cycle.
OFF: Filler wire remains static at the end
of the welding cycle.
AutoWireInch
ON, OFF
Factory setting is ON
Automatic SuperSnake Wire Inch
feature. When ON, the Wire Inch button
drives the filler wire automatically up to
SuperSnake.
Gas Guard
ON, OFF
Factory setting is OFF
Turns the gas guard on and off, provided
that one is installed.
* When connecting a remote control device to the power source in MMA/CC/CV welding,
you don't need to make adjustments to this setting. Remote control device is automatically
recognised, when USER option is selected (default) and RemoteAutoRecog=ON.
19
© Kemppi Oy / 1312