Kemppi Master S 400 Operating Instructions Manual - page 10
EN
3.2.3 Activation and setup parameter adjustment
1.
Press remote selection button (11) for at least 3 seconds, until the text ”Set” appears on
the screen.
2.
Choose the needed parameter with the welding current adjustment knob (6).
3.
To select the required parameter, press the remote selection button (11). You can move
from adjustment mode to selection mode with a new press of the button (11).
4.
Use the Welding current adjustment knob (6) to adjust the parameter value.
5.
You can exit Setup mode with a long press of remote selection button (11). Setup
parameters are saved when you exit Setup.
Setup menu structure
Advanced control panel
Name
Function
Description
Factory
default
Adjustment range
Ant.
Antifreeze
If Antifreeze selection is On, the
machine cuts off the power and protects
the electrode if sticking occurs during
the welding
On
On/OFF
Cab.
Long cables
Long cable mode for welding circuits of
50 m and longer (max. 80 m)
OFF
On/OFF
Gen.
Generator
Generator mode for generator use and
fluctuating mains networks
OFF
On/OFF
CU
CV mode
CV mode selection
OFF
On/OFF
rc
Remote selection
Remote operation mode. Selection
between analog and wireless remote
controllers (R10/R11T)
r10
r10/r11
rcL
Remote low current
limit
Limits the remote adjustment range.
Allows more exact remote adjustment.
30
30–MAX
rcH
Remote high current
limit
Limits the remote adjustment range.
Allows more exact remote adjustment.
MAX
30–MAX
Urd
VRD selection
Reduces open circuit voltage below 35V OFF
(device specific)
On/OFF
Fac.
Restore factory
settings
Restores setup and panel settings to
factory default
OFF
rES/OFF
Constant Voltage (CV)
In CV mode the welding machine maintains a relatively stable, consistent voltage regardless
of the amperage. This mode is recommended to be used with carbon arc gouging and in MIG/
MAG welding with Kemppi voltage sensing wire feed systems. CV mode is activated through
the setup menu.
Voltage Reduction Device (VRD)
Master S 400 and 500 contain a voltage reduction device (VRD), which reduces the open-
circuit voltage below 35 V. This reduces the risk of electric shock in particularly dangerous
environments, such as closed or damp spaces. VRD is activated through the setup menu.
Master S 400, 500
8