Using the KSP8 ADAT–TDIF I/O Option (KADT8)
5
806 MnIn>5.1 AutoPan
807 3 SterIn>5.1 FX+
808 4 SterIn>5.1 FX
809 5.1 In>5.1 FX +
810 Default 5.1+Ster
811 Default 8 Mono
812 Default 4 Stereo
Master Table
Master Page Configuration Parameters
Some ADAT or TDIF configurations require that you set some of the parameters on the KSP8 Master page. Mostly
these have to do with clock selection and TDIF types. Refer to Chapter 10 of the
KSP8 User’s Guide
for information
on the KSP8 Master page.
The connection diagrams that follow this section will help to clarify some of this information.
ClockSource
You will have to set the ClockSource parameter to indicate which device is the master. The choices are:
•
44.1 KHz Internal
•
48 KHz Internal
•
AES/EBU
•
ADAT
•
TDIF
•
Word Clock
TDIF Type
TDIF connection only.
You will only need to set the TDIF Type parameter for TDIF configurations when Clock
Source is Word Clock.
Choose “DA-88” for connection to a TASCAM DA-88. Choose “Other” for all other products (including TASCAM
products other than the DA-88).
TDIF Len
TDIF connection only.
Indicate the word length for your TDIF input data. This should match the word length used
by the sending TDIF device. (The word length for KSP8 output is set with the DigWordLen option, also on the
Master page.)